Date |
Text |
2022-04-27 10:12:50 | 1ST REVIEW FBC-2020 PLUMBING |
| PERMIT- 22040242 |
| 4/27/2022 |
| |
| CODES IN EFFECT: |
| FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 |
| FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 |
| FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION |
| 2020 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) SHEETS PL0.20 & PL0.26: PLEASE IDENTIFY THE LOCATION |
| OF THE WATER FALL FOUNTAIN- SEC. 107.2.1 WPB. |
| |
| 2) PL0.25: SHOW THE TRENCH AND PIPING ROUTE FOR THE |
| WATER FALL FOUNTAIN- SEC. 107.2.1 WPB. |
| |
| 3) PL0.20: THE PLANS APPEAR TO INDICATE THE WATER |
| FOUNTAIN IS NOT FOR BATHING. PLEASE CLARIFY IF SIGNAGE |
| WILL BE PROVIDED AT THE FOUNTAIN TO IDENTIFY THE USE |
| AND RESTRICT BATHERS FROM OCCUPYING THE FOUNTAIN- SEC. |
| 107.2.1 WPB AND SEC. 454.1.2.3.5 FBC B. |
| |
| 4) PL7.15: THE PLAN INDICATES POOL WASTE LINE TO |
| NEAREST AUTHORIZED OUTFALL. PLEASE SHOW THE WASTEWATER |
| PIPING RUN AND DISPOSAL LOCATION. CONCERNING DISPOSAL |
| OF POOL WASETWATER PLEASE NOTE THE FOLLOWING |
| REQUIREMENTS: |
| WASTEWATER SHALL BE DECHLORINATED AND DISCHARGED |
| THROUGH AN AIR GAP IN THE INTO THE STORM DRAINAGE |
| SYSTEM- SEC. 454.1.6.5.15 & SEC. 90-126(5) WPB CODE OF |
| ORDINANCES. THE WASTEWATER SHALL NOT DISCHARGE INTO THE |
| SANITARY SYSTEM. PLEASE REVIEW WPB BUILDING DEPT. |
| GUIDELINES FOR POOL WATER DISPOSAL. THE ENGINEER OF |
| RECORD SHALL SHOW THE DECHLORINATION SYSTEM ON THE PLAN |
| AND PROVIDE SPECIFICATIONS FOR ALL EQUIPMENT. PLEASE |
| SEE GUIDELINES BELOW- |
| SWIMMING POOL WATER MAY BE DISCHARGED TO THE CITY |
| STORMWATER SEWER ONLY IF THE WATER IS DECHLORINATED |
| ACCORDING TO SECTION 90-205(1) OF THE CITY OF WEST PALM |
| BEACH CODE OF ORDINANCES. SUBMIT THE MANUFACTURER'S |
| SPECIFICATION FOR THE DICHLORINATION SYSTEM FOR REVIEW |
| AND STAMPING BEFORE THE INSPECTION. AT THE TIME OF POOL |
| WATER DISCHARGE, THE FOLLOWING WILL BE REQUIRED: |
| |
| A) THE RECEIVING INLET MUST BE PROTECTED (FILTER CLOTH |
| TO KEEP EXCESS SEDIMENTS FROM ROADWAY WASHING INTO THE |
| INLET). |
| B) NO DISCHARGE HOSE CAN BE DIRECTLY INSERTED INTO THE |
| INLET TO DISCHARGE EFFLUENT. |
| C) WHENEVER POSSIBLE, DISCHARGE EFFLUENT SHALL BE |
| ALLOWED TO FILTER THROUGH GRASS AREA ON THE POOL |
| OWNER'S PROPERTY BEFORE DISCHARGING ON CITY PROPERTY. |
| D) DISCHARGE SHALL NOT FLOOD STREETS OR NEIGHBORING |
| PROPERTY. |
| E) FOR TECHNICAL QUESTIONS, CONTACT O&M SUPERINTENDENT |
| STEPHON HARRIS AT [email protected] OR 561-822-2168. |
| F) FOR STORMWATER DISCHARGE COMPLIANCE QUESTIONS, |
| PLEASE CONTACT CHRIS JACKSON, ENVIRONMENTAL COMPLIANCE |
| SPECIALIST III, PUBLIC UTILITIES DEPARTMENT, (561) |
| 822-2062 OR [email protected]. |
| |
| 5) PL7.15: SHOW THE SOURCE OF WATER SUPPLY TO THE |
| FOUNTAIN- SEC. 107.2.1 WPB. IF CONNECTED TO THE POTABLE |
| WATER SERVICE BACKFLOW PROTECTION IS REQUIRED PER THE |
| CITY OF WEST PALM BEACH UTILITIES CROSS-CONNECTION |
| MANUAL. A FL. LICENSED PLUMBING CONTRACTOR SHALL OBTAIN |
| A SEPARATE PERMIT FOR INSTALLATION OF THE BACKFLOW |
| PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB AND SEC. |
| 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL BE |
| TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT |
| PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT. |
| PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS |
| DEPT.AT 561-822-2210 FOR FURTHER INFORMATION. |
| |
| 6) PL7.15: PROVIDE A CLEANING SYSTEM FOR THE WATERFALL |
| FOUNTAIN- SEC. 107.2.1 WPB. |
| |
| 7) PL7.15: SUBMIT MANUFACTURER'S SPECIFICATIONS FOR |
| RECIRCULATION AND TREATMENT EQUIPMENT INCLUDING THE |
| PUMPS, FILTERS, CHEMICAL FEEDERS, AND DRAIN ASSEMBLIES- |
| SEC. 107.2.1 WPB. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |