Text |
2022-04-08 16:29:06 | 1ST REVIEW FMC | | PERMIT: 22031379 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) KEYNOTE 5 IS FOR A MOTORIZED BACKDRAFT DAMPER IN AN | | ACCESSIBLE LOCATION. PLEASE VERIFY THAT THIS | | INSTALLATION WILL MEET FRC M1502.3 AND BE INSTALLED AT | | THE DUCT TERMINATION LOCATION. A BACKDRAFT DAMPER SHALL | | NOT BE INSTALLED IN THE DRYER DUCT SYSTEM. | | | | 2) PLEASE SHOW THE CONDENSATION DRAIN AND TERMINATION | | LOCATION. FRC M1411.3 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|