2022-06-14 10:29:30INSUFFICIENT
  
 1) SHEET E201 SHOWS THAT THE PROPOSED WIRELESS FACILITY
 (POLE) DOES NOT MEET THE CITY OF WEST PALM BEACH
 CONCEALMENT (STEALTH) STYLE REQUIRED BY SECTIONS
 78-411(E) AND 78-411(F) OF THE CITY CODE. NOTE: THE
 COVER SHEET CALLS OUT THE USE OF A RAYCAP STEALTH POLE
 AND THIS IS SHOWN ON OTHER PLAN SHEETS. ALL PLANS NEED
 TO SHOW THE STEALTH FACILITIES. PLEASE NOTE THAT YOU
 NEED TO REMOVE THE EXTERIOR CONDUIT DETAILS FROM SHEET
 A502 (3) AS THESE DO NOT APPLY TO A STEALTH POLE.
  
 2) THIS IS A CITY OF WEST PALM BEACH RIGHT-OF-WAY SO
 YOU USE CITY DETAILS, NOT PALM BEACH COUNTY DETAILS AS
 SHOWN ON SHEET E301.
  
 3) PROVIDE A CROSS SECTION OF THE UNDERGROUND ELECTRIC
 WHICH VERIFIES THAT THERE ARE NO CONFLICTS WITH
 EXISTING UTILITIES.
  
 4) THE POLE COLOR AT THIS LOCATION SHALL BE RAL/RAYCAP
 7022 TRAFFIC GREY A.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446