 6. PARTIALLY SATISFIED. PER SECTION 94-448, CALCULATE
 THE SQUARE FOOTAGE OF TREE CANOPY TO BE REMOVED BASED
 ON THE CANOPY DIAMETER. TREES LESS THAN 20 FEET
 DIAMETER BY CATEGORY, 20 FEET OR MORE BY ACTUAL SQUARE
 FOOTAGE.
  
 MUST SUBMIT A SEPARATE TREE ALTERATION PERMIT IN ORDER
 TO PASS LANDSCAPE PERMIT REVIEW.
  
 MITIGATION TREE CALCULATIONS NEED SOME CORRECTION ON
 THE PLANT LIST SEE BELOW
  
 TOTAL CANOPY MITIGATION DUE- 5358 SQ FT
  
  
 4 BULNESIA CATEGORY 2 =150 SQ FT 600 TOTAL
 1 BISMARCKIA- CATEGORY 3 = 100 SQ FT
 3 SILVER BUTTONWOOD CATEGORY 2 =150 SQ FT 450 TOTAL
 2 GREEN BUTTONWOOD CATEGORY 1=300 SQ FT 600 SQ FT TOTAL
 1 SATIN LEAF CATEGORY 2 = 150 SQ FT.
 2 SILVER DATE PALMS CATEGORY 3= 100 SQ FT 200 TOTAL
  
 7 GREEN BUTTONWOOD CATEGORY 1= 300 SQ FT, 2100 SQ FT
 TOTAL
 8 ILEX CASSINE CATEGORY 2 = 150 SQ FT. 1200 TOTAL
  
 APPLICABLE TOWARD MITIGATION: 5400 SQ FT
  
  
  
  
  
  
  
 RAY CARANCI, SENIOR LANDSCAPE PLANNER