Plan Review Notes
Plan Review Notes For Permit 22030297
Permit Number 22030297
Review Stop B
Sequence Number 1
Notes
Date Text
2022-04-13 17:06:53REMODEL UNITS
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) ACCESSIBLE RESTROOM - PLEASE SHOW THE MIRROR HEIGHT
 DIMENSION FROM THE FLOOR TO THE "REFLECTIVE SURFACE"
 FBC A 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 2) PLEASE SHOW THAT THE DOORS HAVE A 32" CLEAR OPENING
 - FBC A 404.2.3 CLEAR WIDTH.
 DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32 INCHES
 (815 MM) MINIMUM. CLEAR OPENINGS OF DOORWAYS WITH
 SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF
 THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES.
  
 3) DRAWINGS A200 AND A201 SHOW SHOWER GRAB BAR HEIGHTS
 TO THE CENTER OF THE GRAB BAR - SHOULD BE SHOWN TO THE
 TOP OF THE GRIPPING SURFACE - FBC A 609.4 POSITION OF
 GRAB BARS.
 GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION,
 33 INCHES (840 MM) MINIMUM AND 36 INCHES (915 MM)
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE
  
 4) PLEASE SHOW THE SHOWER BENCH DETAILS AND DIMENSIONS
 TO COMPLY WITH FBC A 610.3
  
 5) A SEPARATE PERMIT IS REQUIRED FOR THE PARKING LOT
 RESTRIPING - PLEASE ACKNOWLEDGE THIS.