Plan Review Notes For Permit 22030290 |
Permit Number |
22030290 |
|
Review Stop |
M |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2022-05-02 17:45:19 | 1ST REVIEW FMC | | PERMIT: 22030290 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) IS THIS A CHANGE OF USE? | | | | 2) PLEASE PROVIDE THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FEC 101.5.1.1.2 | | | | 3) PLEASE PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON | | FMC 403.3.1.1 3RD SENTENCE TELLS US TO USE TABLE | | 403.3.1.1 TO FIND THE OCCUPANT COUNT. WE CANNOT USE THE | | EGRESS OCCUPANT COUNTY. | | | | 4) PLEASE SHOW THE ROOF ACCESS. FMC 306.5 | | | | 5) WHY IS THE EXHAUST OF 2 SEPARATE TENANT SPACES BEING | | SHARED? FMC 501.2 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|