2022-03-22 09:24:25 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2020 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 22030012 |
| ADD: 819 8TH STREET |
| CONT: NEWBOLD CONSTRUCTION |
| TEL: 561-644-5764 |
| E-MAIL: [email protected] |
| |
| 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. MARCH 22ND/2022 |
| ACTION: DENIED |
| |
| 1) SEE ZONING COMMENTS 1, 2,& 3 SEPARATE PERMIT ARE |
| REQUIRED FOR FENCE PERMIT, LANDSCAPING PERMIT , |
| IRRIGATION PERMIT & RESTRIPING OF PARKING LOT. |
| |
| 2) SHEET D1 FOR ALL WINDOWS 1-18 (SINGLE SECTION) THE |
| STATEMENT EXISTING WINDOWS ARE NON-IMPACT WINDOWS TO BE |
| REMOVED AND WALL TRIMMED BELOW FOR NEW SILL HEIGHT OF |
| 36 INCHES. ARE THESE WINDOWS TO BE RE-USED? IF SO HOW |
| WILL THEY MEET THE REQUIREMENT IN THE 2020 FBC-BUILDING |
| CODE 1609.1.2.2 LARGE MISSILE IMPACT OR 1609.1.2.4. |
| |
| 3) BOTH THE NOA 20-0428.01 4200/6200 ALUM. FIXED FRAME |
| L. M. I. AND NOA 20-0814.10 CLIPPED EXTRUDED ALUM. TUBE |
| MULLION W/ AND W/O STEEL REINFORCEMENT ARE MISSING |
| COMPLIANCE WITH IDENTIFY GLAZING/ MULLIONS. PLEASE |
| IDENTIFY IN THE PRODUCT APPROVAL BEFORE SUBMITTING TO |
| DESIGNER OF RECORD AND BEFORE SUBMISSION TO THE |
| BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, |
| PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF |
| GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED OR |
| REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND |
| ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2020 FBC-B |
| 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE |
| INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S |
| INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE |
| PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED |
| BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. |
| |
| 4) PLEASE NOTE THE ENGINEERING CALCULATIONS WERE SEALED |
| WITH AN ENGINEERS SEAL FROM SOUTH CAROLINA. FLORIDA |
| STATUTE 471.003?QUALIFICATIONS FOR PRACTICE; |
| EXEMPTIONS. ? |
| (1)?NO PERSON OTHER THAN A DULY LICENSED ENGINEER SHALL |
| PRACTICE ENGINEERING OR USE THE NAME OR TITLE OF |
| ?LICENSED ENGINEER,? ?PROFESSIONAL ENGINEER,? OR ANY |
| OTHER TITLE, DESIGNATION, WORDS, LETTERS, |
| ABBREVIATIONS, OR DEVICE TENDING TO INDICATE THAT SUCH |
| PERSON HOLDS AN ACTIVE LICENSE AS AN ENGINEER IN THIS |
| STATE. |
| |
| 5) A TRANSMITTAL LETTER / NARRATIVE LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| |
| MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| PART-TIME/ SEMI-RETIRED. |
| |
| IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| BACK INTO THE OFFICE CALL |
| (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| THANK YOU. |
| |