2022-05-16 09:52:56****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FBC 107, A SURVEY SHOWING ELEVATIONS IS REQUIRED.
  
 2. FBC 107, REVISE PLAN TO CLARIFY HOW THE BLOCK WILL
 KEEP WATER FROM SEEPING THROUGH ONTO THE ADJACENT
 PROPERTY. THE RETAINING WALL DOES NOT SHOW STUCCO ON
 THE EXPOSED NEIGHBOR'S SIDE, DOES NOT SHOW
 WATERPROOFING OR PAINT ON EITHER SIDE.
  
 3. REVISE PLAN TO STATE WIND DESIGN CRITERIA FBC R 301,
 R 322.
  
 4. SCOPE NOT CLEAR. FOR INSTANCE, S1.1 SHOWS THE POOL
 AND HARDSCAPE FOR THE POOL. PERMIT DESCRIPTION IS SITE
 WALL. FBC 107.