Date |
Text |
2022-03-08 16:33:01 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC SEVENTH EDITION (2020) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| FOUNDATION PERMIT |
| 300 BANYAN BLVD. |
| 12 STORY OFFICE BUILDING AND PARKING GARAGE |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) SUBMIT AN AREA BREAK DOWN OF THE BUILDING. SPECIFY |
| THE BUSINESS AREA, GARAGE AREA, BALCONY AREA, ROOF |
| TERRACE AREA, ETC. FBC AMENDMENTS 107.2.1 |
| |
| 2) SPECIFY THE TYPE OF CONSTRUCTION, NUMBER OF STORIES, |
| BUILDING HEIGHT AND AREAS AND THE TYPES OF OCCUPANCY |
| FOR THE BUILDING, FBC 503 |
| |
| 3) SUBMIT A MANAGEMENT OF TRAFFIC (MOT) PLAN ALONG WITH |
| A SAFEGUARDS DURING CONSTRUCTION PLAN. PROVIDE A |
| DRAWING THAT SHOWS THE LOCATION OF ALL FENCING, |
| BARRIERS, GATES, BARRICADES, LOCATION OF TOWER CRANES, |
| STAGING AREAS, ETC. SPECIFY WHAT METHODS WILL BE |
| EMPLOYED TO PROTECT ADJACENT PROPERTIES DURING THE |
| CONSTRUCTION PROCESS. FBC CHAPTER 33 |
| |
| 4) PROVIDE LIFE SAFETY PLANS. SHOW THE EXITS, THE |
| SEPARATION DISTANCE OF THE EXITS, OCCUPANT LOADS, EXIT |
| CAPACITY, TRAVEL DISTANCES, ETC. FBC CHAPTER 10 |
| THE LIFE SAFETY PLANS NEED TO SHOW THE FOLLOWING: |
| A) NUMBER OF OCCUPANTS IN EACH AREA FBC 1004.1 |
| B) CUMULATIVE OCCUPANT LOADS FBC 1004.1.1 |
| C) EXIT SEPARATION DISTANCE FBC 1015.2.1 |
| D) COMMON PATH OF EGRESS TRAVEL DISTANCE FBC 1014.3 |
| E) EXIT ACCESS TRAVEL DISTANCE FBC 1016.3 |
| F) CLEAR WIDTH OF THE EXIT OR EXIT ACCESS DOORS FBC |
| 1008.1.1 |
| G) CAPACITY OF EGRESS DOORS, OCCUPANT LOAD SERVED AND |
| MEANS OF EGRESS FACTOR FBC1005.3.2 |
| H) DISTRIBUTION OF EGRESS CAPACITY FBC1005.5 |
| |
| 5) THE VALUATION FOR THIS FOUNDATION PERMIT IS LISTED |
| AS $12,087,000.00. BECAUSE THIS PERMIT IS ONLY FOR THE |
| BUILDINGS FOUNDATION, I NEED TO KNOW WHAT THE COST IS |
| FOR JUST THE SCOPE OF WORK THAT WILL BE COVERED BY THIS |
| FOUNDATION PERMIT, SO THAT I CAN ADJUST THE PERMIT |
| VALUATION ACCORDINGLY. I WILL VERIFY THE BUILDINGS |
| TOTAL VALUE WHEN YOU PROVIDE THE TYPE OF CONSTRUCTION |
| AND AREAS OF EACH OCCUPANCY TYPE FOR THE BUILDING. A |
| MORE DETAILED COST BREAK OUT ESTIMATE WILL BE REQUIRED |
| FOR THE VERTICAL CONSTRUCTION PERMIT DUE TO SOME ITEMS |
| THAT REQUIRE SEPARATE PERMITS. FBC AMENDMENTS 109 |
| SEPARATE PERMITS (APPLICATIONS, PLANS, AND FEES) ARE |
| REQUIRED FOR: |
| LIGHT POLES/SITE LIGHTING |
| FIRE ALARM |
| FIRE SPRINKLER |
| LOW VOLTAGE |
| ACCESS |
| LANDSCAPING |
| IRRIGATION |
| PARKING LOT |
| SWIMMING POOLS AND SPAS |
| GENERATORS |
| ALL OTHER ITEMS OTHER THAN BMEP |
| |
| 6) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH |
| OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| |
| |
| |
| |
| |
| |