Plan Review Notes
Plan Review Notes For Permit 22011186
Permit Number 22011186
Review Stop B
Sequence Number 4
Notes
Date Text
2023-03-01 11:03:49NEW DUPLEX (R3) FOURTH BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22011186
 910 4TH ST
  
 PREVIOUS COMMENT:
 2-EGRESS WINDOW DISCUSSED WITH ROBERT BROWN, BUILDING
 OFFICIAL. SINCE THIS IS NEW CONSTRUCTION AND THE
 SPECIFIED WINDOW SIZE IS SMALLER THAN TYPICAL EGRESS
 SIZE AND THE ARCHITECT'S SPECIFIED WINDOW IS BASED ON
 SPECIFIC MANUFACTURER AND SPECIFIC SIZE WITH AN
 ADDITIONAL CONDITION TO MEET THE EGRESS REQUIREMENTS,
 THEN BUILDING OFFICIAL REQUIRES ARCHITECT OF RECORD TO
 SPECIFY ON PLANS HOW THE SPECIFIED WINDOW MEETS THE
 EGRESS REQUIREMENT. THIS IS REQUIRED IN ORDER FOR
 INSPECTOR TO VERIFY THIS CONDITION IN THE FIELD.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. ARCHITECT DOESN'T
 SPECIFY ON PLANS ON PLANS THE SPECIAL CONDITION
 REQUIRED FOR THE EGRESS WINDOW TO COMPLY WITH THE
 EGRESS REQUIREMENTS. THIS ADDITIONAL INFORMATION WAS
 REQUESTED BY BUILDING OFFICIAL FOR INSPECTION PURPOSES.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 16-DEFERRED SUBMITTAL: PRODUCT APPROVALS WILL BE
 SUBMITTED AFTER THE PERMIT IS ISSUED:
 A)ENTRY WOOD DOOR AS SPECIFIED ON PLANS.
 B)WOOD FRENCH DOOR AS SPECIFIED ON PLANS.
 C)SINGLE HUNG WINDOWS.
 D)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO VERIFY PRESSURES. SEC. R301.2.1 FBC-RESIDENTIAL).
 E)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 E)SHINGLES.
  
 18- REVISE ENERGY CALCULATIONS:
 PREVIOUS COMMENT:
 G)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 NEW COMMENTS BASED ON REVISED CALCULATIONS
 H)ITEM #2 WAS CORRECT BUT IT WAS REVISED AND NOW IS
 INCORRECT. IT IS MULTIPLE FAMILY. REVISE AGAIN AS
 REQUIRED.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 I)ITEM #3 WAS CORRECT BUT IT WAS REVISED AND NOW IS
 INCORRECT. IT IS 2 UNITS.
 SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]