Plan Review Notes
Plan Review Notes For Permit 22011186
Permit Number 22011186
Review Stop B
Sequence Number 3
Notes
Date Text
2023-01-23 17:59:11NEW DUPLEX (R3) THIRD BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22011186
 910 4TH ST
  
 1- OK.
  
 PREVIOUS COMMENT:
 2-PARTIALLY ADDRESSED. (DISCUSSED WITH ROBERT BROWN,
 BUILDING OFFICIAL). SINCE THIS IS NEW CONSTRUCTION AND
 THE SPECIFIED WINDOW SIZE IS SMALLER THAN TYPICAL
 EGRESS SIZE AND THE ARCHITECT'S SPECIFIED WINDOW IS
 BASED ON SPECIFIC MANUFACTURER AND SPECIFIC SIZE WITH
 AN ADDITIONAL CONDITION TO MEET THE EGRESS
 REQUIREMENTS, THEN BUILDING OFFICIAL REQUIRES ARCHITECT
 OF RECORD TO SPECIFY ON PLANS HOW THE SPECIFIED WINDOW
 MEETS THE EGRESS REQUIREMENT. THIS IS REQUIRED IN ORDER
 FOR INSPECTOR TO VERIFY THIS CONDITION IN THE FIELD.
  
 RESPONSE:
 NOT ADDRESSED. ARCHITECT DOESN'T SPECIFY ON PLANS ON
 PLANS THE SPECIAL CONDITION REQUIRED FOR THE EGRESS
 WINDOW TO COMPLY WITH THE EGRESS REQUIREMENTS. THIS
 ADDITIONAL INFORMATION WAS REQUESTED BY BUILDING
 OFFICIAL FOR INSPECTION PURPOSES.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 5- WALL SEPARATING THE TWO UNITS.
 PREVIOUS COMMENT:
 A)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR TYPE
 OF "MUD" TO BE USED TO SEAL ALL OPENINGS AND
 PENETRATIONS AS SPECIFIED ON DETAIL 2 ON SHEET A.4.
 (SEC. 107.2.1 CITY AMENDMENTS. SEC. 703.3
 FBC-BUILDING).
  
 ALSO, DETAIL 2 ON SHEET A.4 STATES THAT MASONRY WALL
 BETWEEN UNIT 1 AND UNIT 2 IS A 2 HR WALL. NEED TO
 SPECIFY THE SPECIFIC TYPE OF CONCRETE BLOCK TO BE
 CONSIDERED 2 HOUR. SEE UL ASSEMBLY U905 FOR SPECIFIC
 TYPE AND REVISE AS REQUIRED. PROVIDE COMPLETE DETAIL
 ASSEMBLY.
  
 RESPONSE:
 NOT ADDRESSED. REVISED SHEET A4 STATED ON ARCHITECT'S
 RESPONSE LETTER WAS NOT SUBMITTED.
  
 16-PRODUCT APPROVALS WILL BE SUBMITTED AFTER THE PERMIT
 IS ISSUED:
 A)ENTRY WOOD DOOR AS SPECIFIED ON PLANS.
 B)WOOD FRENCH DOOR AS SPECIFIED ON PLANS.
 C)SINGLE HUNG WINDOWS.
 D)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO VERIFY PRESSURES. SEC. R301.2.1 FBC-RESIDENTIAL).
 E)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 E)SHINGLES.
 F)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 18- REVISE ENERGY CALCULATIONS:
 PREVIOUS COMMENT:
 A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER NAME, BUILDER NAME. SEC. R101.5.1.1.2
 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 BUILDER NAME IS INCORRECT.
  
 PREVIOUS COMMENT:
 F) ROOF TYPE AND MATERIAL SPECIFIED ON SECOND PAGE IS
 INCORRECT. SEE PLANS AND REVISE AS REQUIRED. SEC.
 R101.5.1.1.2 FBC-ENERGY CONSERVATION.
  
 RESPONSE:
 ROOF TYPE IS INCORRECT.
  
 PREVIOUS COMMENT:
 G)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE
 LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 RESPONSE:
 NOT ADDRESSED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  