2023-01-23 17:59:11 | NEW DUPLEX (R3) THIRD BUILDING REVIEW COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #22011186 |
| 910 4TH ST |
| |
| 1- OK. |
| |
| PREVIOUS COMMENT: |
| 2-PARTIALLY ADDRESSED. (DISCUSSED WITH ROBERT BROWN, |
| BUILDING OFFICIAL). SINCE THIS IS NEW CONSTRUCTION AND |
| THE SPECIFIED WINDOW SIZE IS SMALLER THAN TYPICAL |
| EGRESS SIZE AND THE ARCHITECT'S SPECIFIED WINDOW IS |
| BASED ON SPECIFIC MANUFACTURER AND SPECIFIC SIZE WITH |
| AN ADDITIONAL CONDITION TO MEET THE EGRESS |
| REQUIREMENTS, THEN BUILDING OFFICIAL REQUIRES ARCHITECT |
| OF RECORD TO SPECIFY ON PLANS HOW THE SPECIFIED WINDOW |
| MEETS THE EGRESS REQUIREMENT. THIS IS REQUIRED IN ORDER |
| FOR INSPECTOR TO VERIFY THIS CONDITION IN THE FIELD. |
| |
| RESPONSE: |
| NOT ADDRESSED. ARCHITECT DOESN'T SPECIFY ON PLANS ON |
| PLANS THE SPECIAL CONDITION REQUIRED FOR THE EGRESS |
| WINDOW TO COMPLY WITH THE EGRESS REQUIREMENTS. THIS |
| ADDITIONAL INFORMATION WAS REQUESTED BY BUILDING |
| OFFICIAL FOR INSPECTION PURPOSES. |
| SEC. 107.2.1.2 CITY AMENDMENTS. |
| |
| 5- WALL SEPARATING THE TWO UNITS. |
| PREVIOUS COMMENT: |
| A)PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR TYPE |
| OF "MUD" TO BE USED TO SEAL ALL OPENINGS AND |
| PENETRATIONS AS SPECIFIED ON DETAIL 2 ON SHEET A.4. |
| (SEC. 107.2.1 CITY AMENDMENTS. SEC. 703.3 |
| FBC-BUILDING). |
| |
| ALSO, DETAIL 2 ON SHEET A.4 STATES THAT MASONRY WALL |
| BETWEEN UNIT 1 AND UNIT 2 IS A 2 HR WALL. NEED TO |
| SPECIFY THE SPECIFIC TYPE OF CONCRETE BLOCK TO BE |
| CONSIDERED 2 HOUR. SEE UL ASSEMBLY U905 FOR SPECIFIC |
| TYPE AND REVISE AS REQUIRED. PROVIDE COMPLETE DETAIL |
| ASSEMBLY. |
| |
| RESPONSE: |
| NOT ADDRESSED. REVISED SHEET A4 STATED ON ARCHITECT'S |
| RESPONSE LETTER WAS NOT SUBMITTED. |
| |
| 16-PRODUCT APPROVALS WILL BE SUBMITTED AFTER THE PERMIT |
| IS ISSUED: |
| A)ENTRY WOOD DOOR AS SPECIFIED ON PLANS. |
| B)WOOD FRENCH DOOR AS SPECIFIED ON PLANS. |
| C)SINGLE HUNG WINDOWS. |
| D)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE |
| TO VERIFY PRESSURES. SEC. R301.2.1 FBC-RESIDENTIAL). |
| E)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE |
| IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION |
| SCHEDULE. SEE CITY SAMPLE. |
| E)SHINGLES. |
| F)ROOFING UNDERLAYMENT SPECIFIED ON PLANS. |
| |
| 18- REVISE ENERGY CALCULATIONS: |
| PREVIOUS COMMENT: |
| A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, |
| INCLUDING OWNER NAME, BUILDER NAME. SEC. R101.5.1.1.2 |
| FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| BUILDER NAME IS INCORRECT. |
| |
| PREVIOUS COMMENT: |
| F) ROOF TYPE AND MATERIAL SPECIFIED ON SECOND PAGE IS |
| INCORRECT. SEE PLANS AND REVISE AS REQUIRED. SEC. |
| R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| ROOF TYPE IS INCORRECT. |
| |
| PREVIOUS COMMENT: |
| G)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE |
| LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| CONSERVATION. |
| |
| RESPONSE: |
| NOT ADDRESSED. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |
| |