2022-05-13 09:54:051ST REVIEW FMC
 PERMIT: 22011153
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE APPLICATION IS FOR A WALK-IN COOLER UPGRADE FOR
 1109 OKEECHOBEE RD UNIT 6 WITH THE TYPE OF WORK CHECKED
 IS ALTERATION AND REPAIR. SHEET A-100 CLEARLY SHOWS
 THIS IS 2 NEW COOLERS, ONE IN UNIT6 AND ONE IN UNIT 7.
 REVISE THE PERMIT APPLICATION AND THE VALUE TO REFLECT
 THE 2 UNITS AND THE UNITS THEY WILL BE INSTALLED. FBC
 107.2.1
  
 2) PROVIDE A ROOF DRAWING SHOWING THE LOCATION OF THE
 CONDENSING UNITS AND THE ROOF ACCESS. FBC 107.2.1
  
 3) PROVIDE THE MANUFACTURER?S SPECIFICATIONS FOR THE
 COOLERS. FBC 107.2.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  