2022-03-16 09:00:38 | 03/16/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS |
| |
| NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| |
| 1. DONE |
| |
| 2. DONE |
| |
| 3. DONE |
| |
| 4. DONE |
| |
| 5. ON SHEET P-1 DETAIL #1; |
| |
| A. WOULD YOU PLEASE SHOW THE VENTING AND SUPPLY FOR THE |
| ISOMETRIC DIAGRAM PER THE WPB AMENDMENTS TO THE FBC |
| SEC. 107.3.5.3 (12) RESIDENTIAL PLUMBING. THE WASHING |
| MACHINE IS NOT VENTED OR SHOWS A P-TRAP IN-WALL PER THE |
| WPB AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON |
| CONSTRUCTION DOCUMENTS. |
| |
| B. DONE |
| |
| 6. ON SHEET P-1.1 DETAIL #2; |
| |
| A. THE LAV IS SHOWN IN THE WRONG DIRECTION ON ISOMETRIC |
| FOR BATH #2. WOULD YOU PLEASE CORRECT PER THE WPB |
| AMENDMENTS TO THE FBC SEC.107.2.1 INFORMATION ON |
| CONSTRUCTION DOCUMENTS? |
| |
| B. DONE WITH NEW COMMENT; WASHING MACHINE IS NOT VENTED |
| OR SHOW A P-TRAP IN-WALL PER THE WPB AMENDMENTS TO THE |
| FBC SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| |
| C. DONE |
| |
| D. NEW PAGE AND COMMENTS |
| |
| E. DONE |
| |
| |
| ON SHEET P-1.2; |
| |
| A. IN-UNIT C AND D ISOMETRIC DIAGRAM, WASHING MACHINE |
| IS NOT VENTED OR SHOW A P-TRAP IN THE WALL WOULD YOU |
| PLEASE SHOW THE VENTING AND SUPPLY PER THE WPB |
| AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12) RESIDENTIAL |
| PLUMBING. |
| |
| B. WOULD YOU PLEASE SHOW THE CLEANOUT ON THE ISOMETRIC |
| FOR UNITS A AND B PER THE WPB AMENDMENTS TO THE FBC |
| SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| |
| C. ON THE FLAT DRAWING FOR UNITS A AND B, THE LAV, |
| WASHING MACHINE, AND KITCHEN SINKS ARE NOT SHOWN ON THE |
| WALL. WOULD YOU PLEASE CORRECT PER THE WPB AMENDMENTS |
| TO THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION |
| DOCUMENTS? |
| |
| D. IN-UNIT C, THE BATHROOM WITH TUB, THERE IS A WATER |
| CLOSET AND TUB THAT ARE NOT VENTED CORRECTLY. A DOUBLE |
| WYE IS A FITTING THAT WILL VENT BOTH FIXTURES WITHIN |
| THE BATHROOM GROUPS SHALL CONNECT TO THE WET-VENTED |
| HORIZONTAL BRANCH DRAIN. ANY ADDITIONAL FIXTURES SHALL |
| DISCHARGE DOWNSTREAM OF THE HORIZONTAL WET VENT PER THE |
| 2020 FBC R3108.1 HORIZONTAL WET VENT PERMITTED. |
| |
| 7. THESE ARE MULTI-FAMILY DWELLINGS, AND WATER USERS |
| WILL BE REQUIRED TO INSTALL A BACKFLOW PREVENTION |
| ASSEMBLY AT THE POINT OF DELIVERY. THE TYPE OF BACKFLOW |
| ASSEMBLY REQUIRED WILL BE DEPENDENT UPON THE DEGREE OF |
| HAZARD POSED BY THE WATER USER. A REDUCED PRESSURE ZONE |
| BACKFLOW DEVICE WILL BE REQUIRED AT THE WATER METER PER |
| THE CITY OF WEST PALM CROSS UTILITIES DEPARTMENT AND |
| THEIR CONNECTION CONTROL PROGRAM. WOULD YOU PLEASE |
| PROVIDE A NOTE ON PAGE A-1 THAT A BACKFLOW DEVICE IN |
| THE FORM OF AN RPZ IS REQUIRED WITH A PERMIT BY A |
| LICENSED CONTRACTOR PER THE WPB AMENDMENTS TO THE FBC |
| SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS? |
| |
| 8. ON SHEET LS-2, THE PROPOSED VACUUM BREAKER IS A PVB, |
| AND THE CITY OF WEST PALM BEACH CONSIDERS THIS A |
| COMMERCIAL PROPERTY THAT WILL REQUIRE AN RPZ PER THE |
| CROSS-CONNECTION PROGRAM OF THE CITY OF WPB CROSS |
| CONNECTION PROGRAM. THE IRRIGATION SYSTEM WILL REQUIRE |
| A REDUCED PRESSURE ZONE VALVE PER THE DEGREE OF HAZARD |
| DUE TO HIS BEING A COMMERCIAL PROPERTY PER THE 2020 FBC |
| TABLE R 2902.3 APPLICATION FOR BACKFLOW PREVENTERS. |
| WOULD YOU PLEASE CORRECT PER THE WPB AMENDMENTS TO THE |
| FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS? |
| |
| 9. DONE. |
| |
| WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES. |
| A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION, |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA |
| |
| WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON |
| REQUEST. |
| |
| LUIS A. CRESPO |
| PLUMBING PLAN EXAMINER / INSPECTOR |
| EMAIL: [email protected] OFFICE: 561 805-6720 |
| |