2022-03-23 15:42:18 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW |
| COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #22011077. |
| |
| NOTE: |
| ADDITIONS SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1 |
| FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, |
| COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE |
| REQUIREMENTS OF THE FLORIDA BUILDING CODE. |
| |
| NOTE: |
| LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. |
| SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 |
| FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, |
| COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE |
| REQUIREMENTS OF THE FLORIDA BUILDING CODE. |
| |
| 1-LOT DRAINAGE |
| 1- PROPOSED WORK AFFECTS THE LOT DRAINAGE. PROVIDE |
| DRAINAGE PLAN SHOWING HOW THE SURFACE DRAINAGE IS KEPT |
| WITHIN THE LOT AND NOT DIVERTED TO ADJACENT PROPERTIES. |
| PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE |
| FOLLOWING: |
| R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY AMENDMENTS |
| AND SEC. 110.9 CITY AMENDMENTS. |
| NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED |
| GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM |
| ADJACENT PROPERTIES. |
| |
| 2-ENERGY CALCULATIONS SUBMITTED: |
| NOTE: THIS HOUSE IS A CONTRIBUTING HISTORIC HOUSE. |
| ENERGY CALCULATIONS ARE NOT REQUIRED. BUT IF APPLICANT |
| WANTS THEM TO BE PART OF THE CONSTRUCTION DOCUMENTS, |
| THEN REVISE THEM AS FOLLOWS: |
| |
| A)ENERGY CALCULATIONS FORM R405-2020 IS REQUIRED TO BE |
| CERTIFIED AT THE BOTTOM BY THE OWNER, THE OWNER'S |
| ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY |
| THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY |
| SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| B)A/C AREA SPECIFIED ON PAGE 1 DOESN'T MATCH AREA |
| SPECIFIED ON PLANS. REVISE AS REQUIRED TO MATCH. |
| SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| |
| C) DOORS INFORMATION SPECIFIED ON PAGE 3 DOESN'T MATCH |
| PLANS AND PRODUCT APPROVALS. REVISE AS REQUIRED TO |
| MATCH. SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. |
| NOTE: DOORS TO BE CONSIDERED ARE THE ONES SEPARATING |
| A/C AREA FROM NON A/C AREAS. |
| |
| D) BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE |
| LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| CONSERVATION. |
| |
| 3-PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC |
| 61G20-3.001 FOR: |
| (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW |
| PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL |
| PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL): |
| |
| A)METAL SHINGLES. PROVIDE COMPLETE AND CURRENT APPROVED |
| PRODUCT APPROVAL. NEED COMPLETE FLORIDA PRODUCT |
| APPROVAL, INCLUDING FLORIDA PRODUCT APPROVAL COVER PAGE |
| SHOWING THE CURRENT CODE OR MIAMI DADE NOA. |
| IF NONE OF THESE OPTIONS IS AVAILABLE, THEN |
| MANUFACTURER MAY APPLY FOR LOCAL PRODUCT APPROVAL BY |
| SUBMITTING COMPLETE ENGINEERING SIGNED AND SEALED |
| DRAWINGS FOR BUILDING OFFICIAL APPROVAL. FAC |
| 61G20-3.001. |
| |
| B)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE |
| TO AVOID DELAYS/CONFLICTS). |
| |
| C)INSWING ENTRY DOOR AS SHOWN ON PLANS. |
| |
| D)GARAGE EXTERIOR SWING DOOR AS SHOWN ON PLANS. |
| |
| E) STORAGE EXTERIOR DOOR AS SHOWN ON PLANS. |
| |
| F)CABANA BATH DOOR AS SHOWN ON PLANS. |
| |
| G) UNDERLAYMENT SPECIFIED ON PLANS FOR METAL SHINGLES. |
| |
| 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| 5- WIND RESISTANCE OF EXTERIOR SOFFITS: ENGINEER OF |
| RECORD TO PROVIDE COMPLETE DETAILS AND SPECIFICATIONS |
| FOR THE SOFFIT CONSTRUCTION SHOWING COMPLIANCE WITH |
| SEC. R704 FBC-RESIDENTIAL. |
| NOTE: PLANS SPECIFY T & G WOOD CEILING ALT. W.L. & |
| STUCCO. PROVIDE COMPLETE DETAIL/SPECS FOR ALT. W.L. & |
| STUCCO SOFFIT CONSTRUCTION SHOWING COMPLIANCE WITH WIND |
| RESISTANCE. |
| |
| 6- PROVIDE ICC EVALUATION REPORT FOR THE ICYNENE R-20 |
| INSULATION TO VERIFY COMPLIANCE WITH SEC. R316 |
| FBC-RESIDENTIAL. |
| NOTE: ENGINEER TO REVIEW AND APPROVE THE REPORT IN |
| WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. |
| |
| 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION IN NEW |
| ADDITION. ALSO, SPECIFY SIZE FOR NEW ATTIC ACCESS SHOWN |
| IN GARAGE AREA. SEC. R807 FBC-RESIDENTIAL. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE |
| REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |