Date |
Text |
2022-04-13 09:42:29 | FIRE PROVISO COMMENTS: |
| |
| THERE ARE INDCIATIONS OF DOORS TO REMIAN UNLOCKED |
| DURING OPERATION HOURS PER 7.2.1.5. |
| |
| HOWEVER, SHOULD THE NEED APPLY TO THESE DOORS OF OTHERS |
| WITHIN THIS OCCUPANCY, |
| |
| PER NFPA 101 CH 38 NEW BUSINESS OCCUPANCY |
| |
| 38.2.2.2.2* DOOR LOCKING TO PREVENT UNWANTED ENTRY. |
| WHERE |
| APPROVED, DOORS, OTHER THAN THOSE COMPLYING WITH |
| 38.2.11.2, SHALL BE |
| PERMITTED TO BE LOCKED TO PREVENT UNWANTED ENTRY |
| PROVIDED THAT ALL OF |
| THE FOLLOWING CONDITIONS ARE MET: |
| (1) THE LOCKING MEANS SHALL BE CAPABLE OF BEING ENGAGED |
| WITHOUT |
| OPENING THE DOOR. |
| (2) THE UNLOCKING AND UNLATCHING OPERATION FROM THE |
| EGRESS SIDE OF |
| THE DOOR SHALL BE ACCOMPLISHED WITHOUT THE USE OF A |
| KEY, TOOL, OR |
| SPECIAL KNOWLEDGE OR EFFORT. |
| (3) THE RELEASING MECHANISM SHALL OPEN THE DOOR LEAF |
| WITH NOT MORE |
| THAN ONE RELEASING OPERATION. |
| (4) THE RELEASING MECHANISM FOR UNLOCKING AND |
| UNLATCHING SHALL BE |
| LOCATED AT A HEIGHT NOT LESS THAN 34 IN. (865 MM) AND |
| NOT EXCEEDING |
| 48 IN. (1220 MM) ABOVE THE FINISHED FLOOR. |
| (5) LOCKS, IF REMOTELY ENGAGED, SHALL BE UNLOCKABLE |
| FROM THE EGRESS |
| SIDE OF THE DOOR WITHOUT THE USE OF A KEY, TOOL, OR |
| SPECIAL KNOWLEDGE |
| OR EFFORT. |
| (6) THE DOOR SHALL BE CAPABLE OF BEING UNLOCKED AND |
| OPENED FROM |
| OUTSIDE THE ROOM WITH THE NECESSARY KEY OR OTHER |
| CREDENTIAL. |
| (7) THE LOCKING MEANS SHALL NOT MODIFY THE DOOR CLOSER, |
| PANIC HARD WARE, OR FIRE EXIT HARDWARE. |
| (8) MODIFICATIONS TO REQUIRED FIRE DOOR ASSEMBLIES, |
| INCLUDING DOOR |
| HARDWARE, SHALL BE IN ACCORDANCE WITH NFPA 80. |
| |
| A.38.2.2.2.2 THE INTENT OF THIS SECTION IS TO APPLY |
| ONLY WHERE SPECIALIZED |
| SECURITY MEASURES ARE NEEDED TO PREVENT UNWANTED ENTRY. |
| EXAMPLES OF |
| DOORS THAT MIGHT USE THESE PROVISIONS INCLUDE COLLEGE |
| AND UNIVERSITY |
| CLASSROOM DOORS, AREAS OF OFFICE SPACES OPEN TO THE |
| PUBLIC, LABORATORIES, |
| OR INSTRUCTIONAL ROOMS OR SPACES |
| |
| BE MINDFUL OF NFPA 101 CH 38 |
| |
| 38.2.2.2.3* LOCKS COMPLYING WITH 7.2.1.5.5 SHALL BE |
| PERMITTED ONLY ON |
| PRINCIPAL ENTRANCE/EXIT DOORS. |
| |
| A.38.2.2.2.3 THE WORDS ?PRINCIPAL ENTRANCE/EXIT DOORS? |
| DESCRIBE DOORS |
| THAT THE AUTHORITY HAVING JURISDICTION CAN REASONABLY |
| EXPECT TO BE |
| UNLOCKED IN ORDER FOR THE FACILITY TO DO BUSINESS. |
| |
| PLEASE REVIEW AND ENSURE COMPLIANCE. |
| |
| PETER LEDUC |
| FIRE MARSHAL |
| 561-804-4709 |
| [email protected] |
| |
| |