Plan Review Notes
Plan Review Notes For Permit 22010874
Permit Number 22010874
Review Stop NFIP
Sequence Number 1
Notes
Date Text
2022-02-16 16:58:12NFIP PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
  
 1ST REVIEW
  
 FINISHED CONSTRUCTION ELEVATION CERTIFICATE
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATION FOR THIS
 SITE IS AE WITH A BASE FLOOD ELEVATION (BFE) OF 6.0
 NAVD. THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE
 NO. 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF
 FREEBOARD. THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT
 OR ABOVE 8.0 NAVD.
  
 1. THE GARAGE DOOR VENT LETTER SUBMITTED FOR REVIEW BY
 SCPOTT HAMITON, P.E. REFERENCES NOA 20-0922.19 FOR THE
 OHD'S. THIS NOA CANNOT BE LOCATED UNDER MASTER PERMIT
 19080773. SUBMIT NOA 20-0922.19 FOR REVIEW.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 2. THE GARAGE FLOOD VENT LETTER SUBMITTED FOR REVIEW BY
 ROGER PATTERSON JANSSEN, P,E, IS TO RE-INSTALL THE
 FLOOD VENTS TO COMPLY WITH THE REQUIREMENTS OF FEMA'S
 NFIP TECHNICAL BULLETIN 1. SEE REVISED PLAN PAGE A-1.01
 SUBMITTED FOR REVIEW. 2 FLOOD VENTS, MODEL 1540-574,
 SHALL BE INSTALLED IN OHD #102 AND A STACKER VENT,
 MODEL 1540-521 WILL BE INSTALLED ON THE SOUTHWEST
 CORNER OF THE GARAGE.
 PROVIDE THE PRODUCT APPROVALS, FL5822-R7, FOR MODELS
 1540-574 AND 1540-521. INCLUDE THE COVER SHEET,
 EVALUATION REPORT AND INSTALLATION INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE REFERENCE THE ELEVATION CERTIFICATE FOR THE
 FOLLWING COMMENTS:
  
 3. A6. PHOTOGRAPHS. THE CERTIFIER MUST PROVIDE AT LEAST
 2 PHOTOGRAPHS SHOWING THE FRONT AND REAR OF THE
 BUILDING TAKEN WITHIN 90 DAYS FROM THE DATE OF
 CERTIFICATION. PROVIDE A PHOTOGRAPH OF THE FOUNDATION
 SHOWING A REPRESENTATIVE EXAMPLE OF THE FLOOD OPENINGS
 OR VENTS.
 FEMA EC INSTRUCTIONS PAGE 1 OF 9.
  
 4. A7. THE BUILDING DIAGRAM NUMBER IS STATED AS 1B.
 BASED ON THE FOUNDATION OF THE PROPOSED STRUCTURE, THE
 BUILDING DIAGRAM NUMBER SHOULD BE 1A.
 FEMA EC INSTRUCTIONS, PAGE 1 OF 9.
  
 5. A9 B). THE NUMBER OF FLOOD OPENINGS IS STATED AS 4.
 THERE ARE ONLY 3 FLOOD OPENINGS (1 ON THE SW CORNWER OF
 THE BUILDING AND 2 IN OHD #102.
 FEMA EC INSTRUCTIONS, PAGE 2 OF 9.
  
 6. SECTION D - COMMENTS. ITEM #3 REFERENCES FLOOD VENT
 MODEL: SMART VENT 1540-520. THIS MODEL IS NOT USED FOR
 THIS PROJECT, IT SHOULD STATE: MODELS 1540-521 AND
 1540-574.
 PROVIDE THE REFERENCED ICC-ES REPORT FOR THE SMART
 VENTS.
 PROVIDE THE TOP OF SLAB ELEVATION FOR THE FUTURE
 GENERATOR SHOWN ON SITE PLAN SP-1.01, UNDER MASTER
 PERMIT 19080773.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  