Plan Review Notes
Plan Review Notes For Permit 22010450
Permit Number 22010450
Review Stop Z
Sequence Number 3
Notes
Date Text
2022-10-14 15:15:54FAILED
  
 1) REPEAT UPDATED COMMENT: PROVIDE A SURVEY OF THE
 PROPERTY WHICH INCLUDES THE EXISTING SIGN LOCATIONS.
 THE SURVEY IS TO SHOW ALL OF THE EXISTING EASEMENTS AND
 THAT THE SIGNS ARE LOCATED OUTSIDE OF THE EASEMENTS.
 *** WHILE IT IS NOT A SURVEY, IT APPEARS THAT THE PLAN
 SHEET SHOWING ONLY SIGNS E-072 AND E-072 DID USE A
 CUT/PASTE FROM A SURVEY AS ITS BASE INFORMATION. THE
 OVERALL SITE PLAN IS NOT A SURVEY, NOR IS THE BASE
 INFORMATION CUT/PASTE FROM A SURVEY.
  
 2) SIGN E-001
  
 A. REPEAT COMMENT: PROVIDE THE SETBACK FROM THE
 PROPERTY LINE TO THE SIGN. A MINIMUM OF FIVE FEET IS
 REQUIRED. *** CONTRARY TO THE RESPONSE, NO SHEET HAS
 BEEN SUBMITTED SHOWING THE SIGN SETBACK.
 B. SIZE CONFORMS TO THE MASTER SIGN PROGRAM.
  
 3) SIGN E-002:
  
 A. UPDATED COMMENT: IN ACCORDANCE WITH THE JFK NORTH
 CAMPUS DEVELOPMENT REGULATIONS, THIS DIRECTIONAL SIGN
 MUST INCLUDE INFORMATION ON NAVIGATING TO BUILDING
 ENTRANCES ON THE NORTH SIDE OF THE CAMPUS (EX. THE
 PAVILION) SO THAT PATIENTS CAN KNOW WHICH DIRECTION TO
 GO WITHOUT USING THE ONE-WAY SOUTH LANE BY THE ER. ***
 THE SIGN FAILS TO DIRECT USERS TO HEAD WEST (SIDE A) IF
 THEY ARE GOING TO THE BUILDING CURRENTLY SIGNED AS
 PAVILION ON THE NORTH SIDE OF THE CAMPUS. NOTE: IF SIGN
 E-03 IS UPDATED TO HAVE USERS HEAD WEST TO THE
 PAVILION, THIS WOULD NOT BE REQUIRED ON THIS SIGN.
 C. SIZE CONFORMS TO THE MASTER SIGN PROGRAM.
  
 4) SIGN E-003
  
 A. SEE COMMENT 3)A. REGARDING THE REQUIRED WAYFINDING
 TO THE NORTH SIDE OF THE CAMPUS. IT SHOULD BE ON SIDE A
 OF THIS SIGN, BUT IF NOT, IT WILL NEED TO BE ON SIGN
 E-002..
 B. SIZE CONFORMS TO THE MASTER SIGN PROGRAM.
  
 4) SIGN E-013 - APPROVED
  
 SOUTH FACADE
  
 PERMITTED SIGNAGE: 689 SF
 PROPOSED SIGN: 104.75 SF
  
 5) SIGN E-035
  
 A. REPEAT COMMENT: THE PHOTO SHOWING THE NORTH FACADE
 OF THE BUILDING SHOWS AT LEAST ONE OTHER SIGN ON THE
 NORTH FACADE. YOU MUST SUPPLY A BETTER PHOTO(S) WHICH
 SHOWS THE ENTIRE FACADE, NOT BLOCKED BY TREES, AND
 PROVIDE THE DIMENSIONS OF ALL THE SIGNS THAT CURRENTLY
 EXIST. *** WHILE THE INFORMATION PROVIDED FOR THE
 EXISTING SIGN INDICATES THAT THE ALLOWED SQUARE FOOTAGE
 WILL NOT BE EXCEEDED, STAFF IS UNABLE TO VERIFY SINCE
 THE NEW ELEVATION DRAWING REFERENCED IN THE RESPONSE
 COMMENTS WAS NOT PROVIDED.
  
 NORTH FACADE
  
 PERMITTED SIGNAGE: 689 SF
 EXISTING OUTPATIENT SIGN: 94.95 SF
 PROPOSED SIGN: 41 SF
 TOTAL SIGNAGE: 135.95 SF
  
 6) SIGN E-051 - APPROVED
  
 PERMITTED SIGNAGE: 145.5 SF
 PROPOSED SIGN: 40.35 SF
  
 7) SIGN E-061 - APPROVED
  
 8) SIGN E-064 - REMOVED FROM SCOPE.
  
 9) SIGN E-068 - REMOVED FROM SCOPE.
  
 10) SIGN E-072 - APPROVED
  
 11) SIGN E-073 - APPROVED
  
 12) REPEAT COMMENT: PLEASE NOTE THAT YOU ARE MISSING A
 REQUIRED DIRECTIONAL SIGN ON THE WEST SIDE OF THE SITE,
 GENERALLY AT THE TERMINUS OF THE SOUTHERN ENTRY DRIVE
 THAT DIRECTS DRIVERS TO THE NORTH SIDE OF THE CAMPUS.
 THIS SIGN WAS INSTALLED UNDER PERMIT 21061422 AND
 PASSED INSPECTION ON DECEMBER 3, 2021. IF THIS SIGN HAS
 BEEN REMOVED (AS INDICATED IN THE RESPONSE LETTER),
 THEN THE SITE IS IN VIOLATION OF ITS DEVELOPMENT ORDER
 AND STAFF WILL NOT APPROVE THIS PERMIT UNLESS IT
 INCLUDES A REPLACEMENT SIGN. IF THE RESPONSE WAS IN
 ERROR AND THE SIGN STILL EXISTS AND WILL BE CHANGED OUT
 AT A LATER DATE, YOU MUST PROVIDE A PHOTO OF THE
 EXISTING SIGN.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446
 [email protected]
  