2022-02-23 07:33:46****CORRECTIONS****
  
 PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BRIGHT BIKE DOCKING STATIONS (MASTER) PLAN REVIEW.
 501 EVERNIA ST.
 3RD REVIEW
 STATUS: DENIED
  
 BUILDING/STRUCTURAL REVIEW COMMENTS:
 1) RESOLVED.
 2) RESOLVED.
 3) RESOLVED.
 4) RESOLVED.
 5) [NOT ADDRESSED. THIS IS STILL AN ISSUE WHEN THE
 INSTALLATION IS ON PAVERS OR ASPHALT.] THERE IS A NOTE
 ON PAGE 2 OF THE CALCULATIONS FOR THE PAVER CALULATIONS
 WHICH STATES THE CALCULATIONS ARE FOR THE DECO BIKE
 DOCK STANDS TO RESIST HURRICANE WIND LOADS AND ALL
 OTHER ITEMS, BIKES, KIOSK WILL BE REMOVED IN THE EVENT
 OF A HURRICANE. A STORM PREPARATION PLAN WILL BE
 REQUIRED WHICH SPECIFIES THE ITEMS THAT WILL BE
 REMOVED, WHEN THE ITEMS WILL BE REMOVED (AT WHICH TIME
 PRIOR TO THE WIND EVENT), WHO WILL BE RESPONSIBLE FOR
 REMOVING THEM (PROVIDE CONTACT INFORMATION) AND WHERE
 THEY WILL BE STORED. FBC AMENDMENTS 107.2.1
 6) INFORMATIONAL - SEPARATE PERMITS ALONG WITH A
 SURVEY/SITE PLAN WILL BE REQUIRED FOR EACH LOCATION.
 FBC AMENDMENTS 107.2.5
 7) THE PROPOSED ANCHORING METHOD FOR THE EQUIPMENT IS
 TO BE PROVIDED WITH EACH SEPARATE APPLICATION DEPENDING
 ON THE TYPE OF BASE SUBSTRATE AT THAT LOCATION. FBC
 AMENDMENTS 107.2.1
 8) RESOLVED. A 6" THICK CONCRETE SLAB IS REQUIRED IN
 EXPOSURE D LOCATIONS.
 9) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  
 10) NEW COMMENTS: IT APPEARS THAT THERE ARE SOME ISSUES
 WITH THE BRIGHTBIKE SITE PREPARATION LIST.
 - #4 DOCKS ARE TO BE INSTALLED ON ASPHALT (SAME INSTALL
 AS PAVERS) AND THERE IS AN N IN THE STEEL PLATES NEEDED
 COLUMN. THE PLATES ARE REQUIRED.
 - #8 DOCKS ARE TO BE INSTALLED ON 4" CONCRETE SLAB.
 THIS IS AN EXPOSURE D LOCATION. THE ENGINEERING
 REQUIRES 6" SLABS IN EXPOSURE D.
 - #9 DOCK INSTALLATION INFORMATION IS BLANK. THIS IS
 EXPOSURE D AND WILL REQUIRE A 6" SLAB.
 - #13 DOCKS ARE TO BE INSTALLED ON 4" CONCRETE SLAB.
 THIS IS AN EXPOSURE D LOCATION. THE ENGINEERING
 REQUIRES 6" SLABS IN EXPOSURE D.
 - #15 THE FINAL SURFACE INFORMATION IS BLANK.
  
 INFO ONLY - THIS WILL BE INSTALLED AT THE FOLLOWING
 LOCATIONS:
  
 STATION 1 - 22010670
 STATION 2 - 22010671
 STATION 3 - 22010672
 STATION 4 - 22010673
 STATION 5 - 22010674
 STATION 6 - 22010676
 STATION 7 - 22010677
 STATION 8 - 22010678
 STATION 9 - 22010680
 STATION 11 - 22010681
 STATION 12 - 22010683
 STATION 13 - 220100685
 STATION 14 - 22010686
 STATION 16 - 22010687
 STATION 17 - 22010688
 STATION 19 - 22010689
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved