Plan Review Notes
Plan Review Notes For Permit 22010157
Permit Number 22010157
Review Stop P
Sequence Number 1
Notes
Date Text
2022-02-18 12:13:441ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22010157
 2/18/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P1.0 & P1.1: PLEASE CLARIFY WHAT THE 44-INCH
 MEASUREMENTS AT THE LAVATORIES ARE INDICATING-
 SEC.107.2.1 WPB.
  
 2) SHEETS 12.1, P1.0 & P1.1: SHOW THE CENTERLINES OF
 THE NEW LAVATORIES MEASURED FROM THE ADJACENT WALLS-
 SEC. 405.3.1 FBC P.
  
 3) SHEET 12.1: PROVIDE AN ELEVATION DETAIL OF THE NEW
 LAVATORIES SHOWING THE HEIGHTS OF THE SINK RIMS FROM
 THE FINISHED FLOORS, AND THE KNEE AND TOE CLEARANCES-
 SECS 606.2 & 606.3 FBC ACC.
  
 4) SHEET P2.0: TEMPERED WATER IS REQUIRED FOR THE
 LAVATORY SINKS- SEC. 419.5 FBC P. PLEASE PROVIDE A
 MANUFACTURER?S SPEC SHEET FOR THE WATTS #USG MIXING
 VALVE TO VERIFY THE DEVICE IS ASSE 1070 RATED TO
 DELIVER TEMPERED WATER.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved