Date |
Text |
2022-03-08 18:40:46 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #21121068 |
| |
| 1-SURVEY/DRAINAGE PLAN SUBMITTED: |
| A)SITE PLAN & BOUNDARY SURVEY SUBMITTED SHOW "PROPOSED |
| RETAINING WALL" ON THE EAST SIDE. CLEARLY IDENTIFY |
| LOCATION OF PROPOSED RETAINING WALL. AND, PROVIDE |
| COMPLETE DETAILS/SPECIFICATIONS FOR THE RETAINING WALL |
| CONSTRUCTION. SEC. 107.2.5 CITY AMENDMENTS. R401.3 |
| FBC-RESIDENTIAL. |
| |
| B)A SEPARATE PERMIT WILL BE REQUIRED FOR THE |
| CONSTRUCTION OF THE RETAINING WALL. SEC.105.1 CITY |
| AMENDMENTS. |
| |
| 2- ENERGY CALCULATIONS SUBMITTED: |
| A)ENERGY CALCULATIONS FORM R405-2020 IS REQUIRED TO BE |
| CERTIFIED AT THE BOTTOM BY THE OWNER, THE OWNER'S |
| ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY |
| THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY |
| SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| B)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE |
| LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| CONSERVATION. |
| |
| 3- WIND RESISTANCE OF EXTERIOR SOFFITS: |
| TYPICAL WALL SECTION ON SHEET 3-4 ONLY SPECIFIES |
| "METHAL LATH AND STUCCO SOFFIT W/ 7"X24" SCREENED VENTS |
| @ 8'-0" O.C.". THERE ARE NO SPECIFICATIONS FOR |
| SHEATHING TO SUPPORT THE METHAL LATH. ENGINEER OF |
| RECORD TO PROVIDE CALCULATIONS SHOWING THAT THIS SOFFIT |
| SPECIFICATIONS WITHOUT SHEATHING ARE ADEQUATE TO RESIST |
| THE WIND LOADS AS REQUIRED BY SEC. R704 FBC-RESIDENTIAL |
| OR REVISE DETAIL PROVIDING COMPLETE SHEATHING |
| SPECIFICATIONS (MATERIAL, THICKNESS AND FASTENING). |
| SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.2.1 |
| FBC-RESIDENTIAL. |
| |
| 4-PRODUCT APPROVALS |
| PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC 61G20-3.001 |
| FOR |
| (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| SUBMITTAL): |
| |
| A)REAR FRENCH DOOR AS SHOWN ON PLANS. |
| |
| 5-DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVAL AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| 6- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO |
| LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, |
| CONTRACTOR'S OVERHEAD AND PROFIT AND DESIGN |
| PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| AMENDMENTS. VALUATION WAS UPDATED TO $256,270. THE |
| PERMIT FEE BALANCE IS $1864.99. |
| |
| 7- CLARIFY WHY SUBMITTING PRODUCT APPROVALS FOR |
| OVERHEAD GARAGE DOORS AND SLIDING GLASS DOORS. DRAWINGS |
| DON'T SHOW ANY. SEC. 107.2.1 CITY AMENDMENTS. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE |
| REVISION MADE WILL HELP TO EXPEDITE THE REVIEW PROCESS. |
| THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |
| |