Plan Review Notes
Plan Review Notes For Permit 21120302
Permit Number 21120302
Review Stop ENG
Sequence Number 2
Notes
Date Text
2022-09-08 09:17:301) SHEET B-1 SURVEY INCORRECTLY IDENTIFIES A SANITARY
 SEWER MANHOLE AND SHOWS AN UNDERGROUND SANITARY SEWER
 LINE GOING NORTH. THIS IS A AIR RELEASE VALVE FOR A 30"
 FORCE MAIN THAT RUNS NORTH AND SOUTH OF THIS STRUCTURE.
 IF THIS SURVEY IS ONLY ABOVE GROUND IMPROVEMENTS,
 PLEASE DO NOT INCORRECTLY SHOW UNDERGROUND
 IMPROVEMENTS. IF THE SURVEY SHOWS UNDERGROUND
 IMPROVEMENTS, ALL UNDERGOUND IMPROVEMENTS MUST BE SHOWN
 CORRECTLY.
  
 2) PLEASE SHOW OFFSETS OF A 5' MINIMUM DISTANCE FROM
 THE OUTER EDGE OF THE POLE AND FOUNDATION TO THE OUTER
 EDGE OF THE CITY'S 24" WATERMAIN. THIS DISTANCE MUST BE
 MAINTAINED AS THIS IS A MAJOR WATER TRANSMISSION MAIN
 SERVING THE NORTH END OF THE CITY. SOFT DIGS MUST BE
 DONE PRIOR TO SETTING THE POLE TO VERIFY THE EXACT
 LOCATION OF THE CITY'S 24" WATERMAIN.
  
 3) PLEASE USE EXTREME CAUTION WHEN BORING IN THIS AREA
 AND MINIMUM DISTANCES TO CITY UTILITIES MUST BE
 MAINTAINED.
  