Date |
Text |
2022-01-04 09:59:14 | 1. SITE SURVEY (B-1) IS MISSING AN ADDITIONAL OVERHEAD | | WOODEN DISTRIBUTION POLE, DIRECTLY ADJACENT TO THE POLE | | WHERE THE PROPOSED ELECTRICAL HOOKUP TAKES PLACE. | | PLEASE ADJUST SITE SURVEY AND DRAWINGS TO ACCURATELY | | REFLECT CURRENT SITE CONDITIONS. | | | | 2. CONCRETE CAISSON IS SHOWN ON SURVEY TO CONFLICT WITH | | EXISTING GAS LINE, PLEASE PROVIDE THE NECESSARY PUBLIC | | UTILITY LETTER GRANTING APPROVAL OF THIS PROPOSED POLE | | LOCATION AND DEPTH. | | | | 3. POLE & UNDERGROUND ELECTRIC SHOWN ON DRAWINGS TO | | CONFLICT WITH EXISTING GAS LINES, PLEASE PROVIDE THE | | NECESSARY PUBLIC UTILITY LETTERS GRANTING APPROVAL OF | | THIS PROPOSED BORE PITS, UNDERGROUND ELECTRIC, AND POLE | | LOCATIONS. | | | | 4. PLEASE PROVIDE A TYPICAL CROSS-SECTION SHOWING THE | | DEPTH OF THE UNDERGROUND ELECTRICAL COMPONENTS. | | | | 5. THE POLE STEALTH DESIGN MEETS CITY STANDARDS. | | | | CHRIS KIMMERLY @ (561)822-1426 | | [email protected] | | |
|