Plan Review Notes For Permit 21120055 |
Permit Number |
21120055 |
|
Review Stop |
Z |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2021-12-29 14:17:22 | 12/29/21- FAILED. PLEASE COMPLY WITH THE FOLLOWING | | CONDITIONS OF APPROVAL FROM THE ISPR | | | | PLEASE NOTE THAT THIS APPROVAL IS GRANTED SUBJECT TO | | THE FOLLOWING CONDITIONS: | | | | 1. PRIOR TO THE ISSUANCE OF ANY PERMIT, A UNITY OF | | TITLE SHALL BE RECORDED (TO UNIFY THE SOUTHERN LOT). | | APPLICATION FOR UNITY OF TITLE SHOULD BE MADE THROUGH | | THE CITY?S ENGINEERING SERVICES DEPARTMENT. | | | | 2. REMOVE THE PIPED CONNECTIONS BETWEEN THE MAIN | | STORMWATER MANAGEMENT SYSTEM (INCLUDING THE | | EXFILTRATION SYSTEM) AND THE TRENCH DRAINS ACROSS THE | | DRIVEWAYS AT THE BACK OF SIDEWALK. THIS PIPED | | CONNECTIONS LIMIT THE HYDRAULIC HEAD THAT CAN BE | | IMPOSED ON THE MAJOR EXFILTRATION SYSTEM. THE TRENCH | | DRAINS WILL REDUCE THE AMOUNT OF STORMWATER RUNOFF | | FLOWING FROM THE SITE ACROSS THE SIDEWALK AND SHOULD BE | | CONNECTED TO SEPARATE EXFILTRATION TRENCHES OR | | RETENTION AREA(S) TO TREAT THE STORMWATER RUNOFF | | CAPTURED BY THE TRENCH DRAINS. | | 3. PRIOR TO THE REMOVAL OR RELOCATION OF ANY TREES ON | | THE PROPERTY, A TREE ALTERATION PERMIT SHALL BE | | SUBMITTED, REVIEWED, AND APPROVED BY THE DEVELOPMENT | | SERVICES DEPARTMENT, PLANNING DIVISION. | | | | ANGELLA VANN | | 561-822-1441 | | [email protected] |
|