2022-01-27 16:03:3901/27/22 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. ON SHEET A0.02 AND A1.11, A1.12, A1.14, AND A4.21;
  
 A. WOULD YOU PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE
 URINAL PER THE 2020 FBC ACC SEC. 606.2. 2 CLEAR FLOOR
 SPACE.
  
 B. WOULD YOU PLEASE SHOW THE CLEAR FLOOR SPACE FOR THE
 DRINKING FOUNTAIN PER THE 2020 FBC ACC SEC. 606.2. 2
 CLEAR FLOOR SPACE.
  
 C. WOULD YOU PLEASE LABEL THE WOMEN?S AND MEN?S
 RESTROOMS PER THE WPB AMENDMENTS TO THE FBC SEC. 105.1.
  
 2. ON SHEET A0.04;
  
 A. THE TOILET GRAB BAR SAYS 6 INCHES FROM THE WALL,
 WHICH IS NOT AN ACTUAL NUMBER AS THE TOILET IS 16
 INCHES TO 18 INCHES TO THE CENTER, AND THAT NUMBER MAY
 CONFUSE THE INSTALLER. WOULD YOU PLEASE CORRECT PER THE
 2020 FBC ACC SEC. 604.2 LOCATION AND WPB AMENDMENTS TO
 THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS?
  
 B. WOULD YOU PLEASE PROVIDE DETAIL FOR THE PARTITIONS
 PRIVACY SHALL EXTEND NOT LESS THAN 60 INCHES ABOVE THE
 FINISHED FLOOR SURFACE PER THE 2020 FBC SEC. P 405.3.5
 URINAL PARTITIONS.
  
 C. WOULD YOU PLEASE PROVIDE DETAIL FOR THE HIGH AND LOW
 DRINKING FOUNTAINS THAT SHALL BE ACCESSIBLE IN
 ACCORDANCE WITH 2020 FBC ACC SEC. 211.2 & 602.1- 602.6.
 PROVIDE DRAWINGS AND DETAILS SHOWING; THE 30 X 48 IN.
 CLEAR FLOOR SPACE FOR A FORWARD APPROACH TO THE
 WHEELCHAIR ACCESSIBLE DRINKING FOUNTAIN 2020 FBC ACC
 SEC. 602.2 CLEAR FLOOR SPACE AND PLEASE SHOW KNEE AND
 TOE CLEARANCES, SPOUT HEIGHTS, SPOUT LOCATIONS PER THE
 2020 FBC ACC SEC. 306, 307, & 602.2, COMPLIANCE WITH
 2020 FBC ACC SEC. 307.2 PROTRUSION LIMITS.
  
 3. ON SHEET P0.1;
  
 A. THE DRINKING FOUNTAIN AND THE MOP SINK ARE NOT SHOWN
 ISOMETRICS. WOULD YOU PLEASE CORRECT AND IF THEY ARE
 PREEXISTING WOULD NOT THAT PER THE WPB AMENDMENTS TO
 THE FBC SEC.107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 B. THE SERVICE SINK (MOP SINK) SURROUNDING THE WALL
 SHALL BE A NON-ABSORBENT SURFACE IN ACCORDANCE WITH THE
 2020 FBC BUILDING SEC. 1210.2.2 AND 2020 FBC SEC. P
 310.3. PLEASE MAKE A NOTE ON THIS SHEET.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 WEST PALM BEACH AMENDMENTS 2017 FBC CHAPTER; UPON
 REQUEST.
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR
 EMAIL: [email protected] OFFICE: 561 805-6720
  