2022-01-14 12:44:29ADDITION AND ALTERATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A0.0 IN PROJECT DATA - SHOWS THE FBC 2017 -
 THE CODE IN EFFECT IS FBC 2020 - PLEASE CORRECT.
  
 2) THE ADDRESS SHOWN ON THE PLANS DOES NOT MATCH THE
 ADDRESS SHOWN ON THE BUILDING PERMIT APPLICATION -
 PLEASE CORRECT - THEY SHOULD MATCH.
  
 3) PLEASE SHOW THE RESTROOM AND MOP SINK AREA WALL
 FINISH TO COMPLY WITH FBC 1210.2.2 WALLS AND
 PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)
  
 4) PLEASE SHOW THE WIDTH OF THE RESTROOM HALLWAY
 (MARKED CORRIDOR) FBC WPB 107.2.1
  
 5) IN THE PRODUCT APPROVAL PROVIDED FOR THE FLAT DECK
 ROOFING - PLEASE CIRCLE THE ROOFING SYSTEM TO BE USED
 IN THE ROOFING PRODUCT APPROVAL - ROOFING SYSTEM TO BE
 USED ON THE PROVIDED PRODUCT APPROVAL MAY REQUIRE
 ADDITIONAL SIGNED AND SEALED ATTACHMENT DETAILS FROM AN
 ARCHITECT OR ENGINEER FOR ROOF WIND ZONES 2 AND 3 WHICH
 REQUIRE A HIGHER PRESSURE THAN THE MAXIMUM SHOWN ON THE
 PRODUCT APPROVAL - SEE GENERAL LIMITATION NOTES ON THE
 PRODUCT APPROVALS.
  
 6) ACCESSIBLE RESTROOM - PLEASE SHOW THE LOCATION
 DIMENSIONS FOR THE TOILET PAPER HOLDER PER FBC A604.7
 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND
 SHALL NOT BE LOCATED BEHIND GRAB BARS.
  
 7) ACCESSIBLE RESTROOM - PLEASE SHOW THE LOCATION
 DIMENSIONS AND THE LENGTH FOR THE TOILET REAR GRAB BAR
 FROM THE CENTER OF THE TOILET PER FBC A 604.5.2 REAR
 WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 8) ACCESSIBLE RESTROOM - PLEASE SHOW THE DIMENSION FOR
 THE MIRROR FROM THE FINISHED FLOOR TO THE BOTTOM OF THE
 "REFLECTING SURFACE" PER FBC A 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 9) ACCESSIBLE RESTROOM - DOORS CANNOT SWING INTO THE
 REQUIRED FIXTURE FLOOR SPACE - FBC A603.2.3 DOOR SWING.
 DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE OR
 CLEARANCE REQUIRED FOR ANY FIXTURE. EXCEPTIONS: 2.
 WHERE THE TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL
 USE AND A CLEAR FLOOR SPACE COMPLYING WITH 305.3 IS
 PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR
 SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR
 FLOOR SPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE.
 (PLEASE SHOW THE CLEAR FLOOR SPACE FOR THIS EXCEPTION)
  
 10) PLEASE SHOW THE HEIGHT OF THE CUSTOMER SERVICE
 COUNTER TO COMPLY WITH FBC 904.4.1PARALLEL APPROACH.
 A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES (915
 MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM
 ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR
 OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED
 FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH (915
 MM) MINIMUM LENGTH OF COUNTER.
  
 11) PLEASE SHOW THE DIMENSIONS FOR THE EXTERIOR
 CUSTOMER SERVICE COUNTER (WALK UP) TO COMPLY WITH FBC
 904.4.1PARALLEL APPROACH.
 A PORTION OF THE COUNTER SURFACE THAT IS 36 INCHES (915
 MM) LONG MINIMUM AND 36 INCHES (915 MM) HIGH MAXIMUM
 ABOVE THE FINISH FLOOR SHALL BE PROVIDED. A CLEAR FLOOR
 OR GROUND SPACE COMPLYING WITH 305 SHALL BE POSITIONED
 FOR A PARALLEL APPROACH ADJACENT TO THE 36 INCH (915
 MM) MINIMUM LENGTH OF COUNTER.
  
 12) PLEASE SHOW THE REQUIRED DINING SEATING PER FBC
 226.1 GENERAL.
 WHERE DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION
 OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING
 SPACES AND STANDING SPACES AT THE DINING SURFACES SHALL
 COMPLY WITH 902.
  
 13) PLEASE SHOW THAT A SEPARATE PERMIT IS REQUIRED FOR
 THE DUMPSTER AREA WHICH IS ON A SEPARATE PROPERTY.
  
 13) PLEASE PROVIDE DETAILS FOR THE SCREEN ENCLOSURE OR
 STATE THAT THE SCREEN ENCLOSURE WILL BE ON A SEPARATE
 PERMIT.
  