Plan Review Notes
Plan Review Notes For Permit 21110845
Permit Number 21110845
Review Stop M
Sequence Number 2
Notes
Date Text
2021-12-29 06:06:10IT APPEARS THAT THE 1ST LEVEL APARTMENT AHU IS LOCATED
 IN A CLOSET AND I DO NOT SEE A RETURN AIR GRILL DUCTED
 TO OUTSIDE OF THE CLOSET. PLEASE SHOW HOW THE RETURN
 AIR PATH IS NOT USING THE CLOSET TO GET BACK TO THE
 AHU. FBC RES M1602.2-4
  
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  