Date |
Text |
2022-02-02 10:35:55 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2020 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 21110826 |
| ADD: 1900 CONSULATE PL. # 803 |
| CONT: TO BE DETERMINED/ CONTRACTOR NEEDS TO REGISTER |
| TEL: 3053705679 |
| E-MAIL: [email protected] |
| |
| 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: WED. FEB. 02/2022 |
| ACTION: DENIED |
| |
| 1A) THE 4 SUBMITTED FLOOR PLANS IT APPEARS THE CGC IS |
| TAKING OWNERSHIP OF THE BUILDING PLANS, ELECTRICAL PLAN |
| AND PLUMBING PLAN. TO DO SO THE CGC WOULD HAVE TO BE |
| LICENSED IN ALL 3 TRADES, SEE WEST PALM BEACH AMENDMENT |
| 107.3.4.3 CERTIFICATION BY CONTRACTOR. PLEASE NOTE THE |
| EXCEPTION TO ENGINEERED PLANS UNDER 471.003(H) |
| ELECTRICAL/ PLUMBING/ MECHANICAL, 481.229(1)(C) |
| REQUIRES THE CONTRACTOR FOR THAT TRADE THAT WILL BE |
| LICENSED IN THAT TRADE, WILL ALSO BE THE CONTRACTOR |
| THAT DESIGNS THE SYSTEM UNDER THAT TRADE. THE |
| CONTRACTOR (QUALIFIER) THAT CREATED / DREW THE SET OF |
| PLANS WILL NEED TO IDENTIFY THEMSELVES AS THE AUTHOR OF |
| THE PLANS. PLEASE PRINT YOUR NAME, SIGN YOUR NAME AND |
| LICENSE NUMBER FOR THE TRADE YOU ARE LICENSED IN AND |
| PLANS DRAWN. |
| FOR EACH TRADE THE CONTRACTOR RESPONSIBLE FOR THE |
| DESIGN UNDER THE TRADE LICENSED IN MUST PRINT THEIR |
| NAME, SIGN THEIR NAME AND LICENSE NUMBER, NOTE THESE |
| PLANS APPEAR TO BE DRAWN BY ONE INDUVIAL, THEY WOULD |
| HAVE TO BE LICENSED AS A BUILDING, ELECTRICAL AND |
| PLUMBING CONTRACTOR TO SUBMIT ALL THESE TRADES UNDER |
| ONE SHEET. |
| |
| 1B) PLEASE NOTE THE DOLLAR AMOUNT ON THE PERMIT |
| APPLICATION UNDER VALUE OF WORK AT $91,150.00 OF VALUE. |
| PLEASE REVIEW THE FL. STATUTE 481.229 EXCEPTIONS; |
| EXEMPTIONS FROM LICENSURE (1) |
| (C) ANY OTHER TYPE OF BUILDING COSTING LESS THAN |
| $25,000.00, EXCEPT A SCHOOL, AUDITORIUM, OR OTHER |
| BUILDING INTENDED FOR PUBLIC USE, PROVIDED THAT THE |
| SERVICES OF A REGISTERED ARCHITECT SHALL OT BE REQUIRED |
| FOR MINOR SCHOOL PROJECTS PURSUANT TO 1013.45. |
| |
| YOUR DOLLAR AMOUNT OF $91,150.00 DOLLARS EXCEEDS THE |
| EXCEPTION FOR A DESIGN PROFESSIONAL. |
| 1C) THE TITLEBLOCK ALSO INDICATES A DESIGN |
| PROFESSIONAL, TEAM ARCHITECTURE, INC. REGISTERED |
| ARCHITECT FERNANDO R. PRIETO AS THE DESIGNER OF RECORD. |
| YOU CAN NOT USE COPYRIGHTED WORK. 61G15-23.004 |
| PROCEDURES FOR SIGNING AND SEALING ELECTRONICALLY |
| TRANSMITTED PLANS (DIGITAL SIGNATURES), SPECIFICATIONS, |
| REPORTS OR OTHER DOCUMENTS, REQUIRE 3RD PARTY |
| VERIFICATION. |
| 2) THE EXISTING FLOOR PLAN NOTE 2 INDICATES THE REMOVAL |
| OF ALL CARPETED AREAS AND INSTALLING NEW TILE & VINYL |
| FLOORING. THE PROPOSED FLOOR PLAN NOTE STATES NEW TILE |
| FLOORING, THE ONLY AREA NOTE 2 IS SHOWN IS THE LIVING |
| ROOM. PLEASE PROVIDE THE SQUARE FOOTAGE FOR THE TILE & |
| WHERE TILE IS TO BE INSTALLED AND PLEASE PROVIDE THE |
| SQUARE FOOTAGE FOR THE VINYL FLOORING & WHERE VINYL IS |
| TO BE INSTALLED. 107.2.1.2. ADDITIONAL INFORMATION IS |
| REQUIRED FOR CODE COMPLIANCE. |
| 3) SINCE THE SCOPE OF FLOORING INVOLVES BOTH TILE |
| FLOORING AND VINYL FLOORING (LVT OR LVP) BOTH TYPES OF |
| FLOORING WILL NEED TO SUBMIT TESTING FOR THE |
| UNDERLAYMENT AND FINISH FLOOR. |
| FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, |
| STONE, MARBLE, VINYL (LVT / LYP), LAMINATE FLOORING AND |
| WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND |
| UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING |
| STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH |
| OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ |
| NO DROPPED CEILING: |
| PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR |
| TYPE II BUILDINGS SHOWING COMPLIANCE WITH: |
| |
| 3A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. |
| FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. |
| |
| 3B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, |
| PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING |
| DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR |
| SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS |
| (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR |
| AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E |
| 90. |
| |
| 3C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. |
| INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID |
| DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED |
| TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. |
| FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS |
| A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL |
| MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A |
| MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. |
| |
| LVT & LPT LUXURY VINYL TILE. FLOOR FINISH |
| CLASSIFICATION AS REQUIRED IN SECTION 804.2 |
| CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF |
| THE 2020 FBC-B. |
| 4) THE PROPOSED FLOOR PLAN NOTE 5 INDICATES NEW DROPPED |
| CEILINGS THROUGHOUT ALL OF THE TENANT SPACE BUT THERE |
| IS NO DROPPED CEILING DETAIL SHOWING THE DROPPED |
| CEILING FRAMING MEMBER, SIZE, SPACING, ANCHOR SIZE OR |
| ANCHOR SPACING INTO THE CONCRETE DECK ABOVE THE TYPE OF |
| CEILING MATERIAL, NOR THICKNESS. MISSING INFORMATION. |
| 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION 107.2.1. DRAWINGS & |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. CONSTRUCTION DOCUMENTS SHALL BE |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. |
| 5) PLEASE PROVIDE ADDITIONAL INFORMATION IN REGARDS TO |
| NOTE 6 NEW KITCHEN SOFFITS. KITCHEN SOFFIT CEILING |
| FRAMING MEMBER, SIZE, SPACING, ANCHOR SIZE OR ANCHOR |
| SPACING INTO THE CONCRETE DECK ABOVE THE TYPE OF |
| CEILING MATERIAL, NOR THICKNESS. MISSING INFORMATION. |
| 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| CODE, CHAPTER 1, ADMINISTRATION 107.2.1. DRAWINGS & |
| SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| TECHNICAL CODES. CONSTRUCTION DOCUMENTS SHALL BE |
| SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| DETERMINED BY THE BUILDING OFFICIAL. |
| 6) BOTH BATHROOMS INDICATE WITH NOTE 13 NEW SHOWERS NO |
| ADDITIONAL INFORMATION WAS SUBMITTED. PLEASE SHOW |
| COMPLIANCE WITH SECTIONS: 2020 FBC-B 1210.2.2. WALLS & |
| PARTITIONS. THIS COMMENT IS A RESULT OF THE BUILDING |
| OFFICIAL INTERPRETATION ON 06/2020. IN BATHROOMS, |
| RESTROOMS & SERVICE SINK AREAS EPOXY PAINT IS NO LONGER |
| CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. |
| |
| 6A) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF WATER |
| CLOSETS SHALL HAVE A SMOOTH, HARD, NON-ABSORBENT |
| SURFACE TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE |
| FLOOR, EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIAL |
| USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT |
| ADVERSELY AFFECTED BY MOISTURE. |
| |
| 6B) 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET WALLS |
| SHALL COMPLY WITH 1210.2. |
| |
| 6C) 1210.2. FINISH MATERIALS. WALLS, BASE, FLOORS AND |
| PARTITIONS IN TOILET AND BATHROOMS SHALL COMPLY WITH |
| SECTIONS 1210.1 THROUGH 1210.4. |
| 6E) 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS |
| A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS |
| AND CEILING PANELS IN SHOWER AREAS SHALL BE OF |
| MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN |
| ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER |
| RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE |
| FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN |
| INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND |
| THE MANUFACTURE?S RECOMMENDATIONS. |
| |
| 6F) 2020 FBC-B SHOWERS & TUBS 1210.3. SHOWER |
| COMPARTMENTS AND BATHTUBS WITH INSTALLED SHOWER HEADS |
| SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A |
| HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. |
| 7) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| |
| AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING |
| FROM CITY HALL. |
| MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| PART-TIME/ RETIRED. |
| |
| IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| BACK INTO THE OFFICE CALL |
| (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| THANK YOU. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| |
| |
| |
| |