Plan Review Notes
Plan Review Notes For Permit 21110446
Permit Number 21110446
Review Stop P
Sequence Number 1
Notes
Date Text
2021-11-29 11:56:1711/29/21 1ST PLUMBING REVIEW**DENIED** WITH COMMENTS
  
 NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS
 TIME, AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE
 GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1. PLEASE PROVIDE A PLUMBING ISOMETRIC RISER DIAGRAM
 PER THE WPB AMENDMENTS TO THE FBC SEC. 107.3.5.3 (12)
 RESIDENTIAL PLUMBING.
  
 2. THE MASTER BATHROOM IS NOT VENTING THE TUBS
 CORRECTLY AND THE BATHROOM GROUP NEED TO BE SEPARATE
 FROM THE BUILDING DRAIN CATCHING OTHER FIXTURES UP
 STREAM PER THE 2020 FBC SEC. R P3101.2.1 VENTING
 REQUIRED AND P 3108.2.1HORIZONTAL WET VENT.
  
 3. WOULD YOU PLEASE SHOW LOCATION OF THE NEW WATER
 HEATER PER THE WPB AMEND TO FBC 107.2.1
  
 WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY NECESSARY PAGES.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND, WILL HELP EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 HTTPS://CODES.ICCSAFE.ORG/CODES/FLORIDA
  
 LUIS A. CRESPO
 PLUMBING PLAN EXAMINER / INSPECTOR