Plan Review Notes
Plan Review Notes For Permit 21110017
Permit Number 21110017
Review Stop B
Sequence Number 2
Notes
Date Text
2022-04-22 16:26:57RESIDENTIAL (R3) ALTERATION SECOND BUILDING AUDIT.
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21110017 (GUEST HOUSE)
  
 NOTE:
 THIS IS A LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING
 BUILDING. SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 1- OK.
 2- OK.
  
 ORIGINAL COMMENT:
 3- SECOND FLOOR BEDROOM EGRESS WINDOWS DON'T SEEM
 COMPLY WITH SEC. R310.2.1 FBC-RESIDENTIAL. REVISE AS
 REQUIRED. SHOW COMPLIANCE WITH MIN. CLEAR OPENINGS
 (WIDTH, HEIGHT AND TOTAL CLEAR OPENING).
  
 RESPONSE:
 REPEAT COMMENT. NO ADDRESSED. UNABLE TO VERIFY EGRESS
 WINDOW.
  
 ORIGINAL COMMENT:
 4- PLANS DON'T PROVIDE ANY INFORMATION ABOUT SECOND
 FLOOR WINDOW FALL PROTECTION. WINDOW FALL PROTECTION
 SHALL BE PROVIDED ON SECOND FLOOR WINDOWS WHERE THE TOP
 OF THE WINDOW SILL OF AN OPERABLE WINDOW IS LOCATED
 LESS THAN 24" ABOVE THE FINISHED FLOOR . SEC. R312.2
 FBC RESIDENTIAL.
 NOTE: CLEARLY INDICATE THE WINDOW SILL HEIGHT OF SECOND
 FLOOR WINDOWS AND SPECIFY TYPE OF WINDOW FALL
 PROTECTION IS REQUIRED.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED. UNABLE TO VERIFY IF
 WINDOW FALL PROTECTION IF REQUIRED
  
 ORIGINAL COMMENT:
 5- PLANS DON'T PROVIDE ANY INFORMATION FOR THE NEW
 SPIRAL STAIR.
 UNABLE TO CHECK EGRESS. SEC. R311.7.10.1
 FBC-RESIDENTIAL. SPECIFY STAIR SIZE AND TREAD AND
 RISERS DIMENSIONS. PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS FOR CONSTRUCTION: FOOTING,
 ANCHORING, ETC. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 PLANS DON'T SPECIFY SIZE OF SPIRAL STAIR. UNABLE TO
 VERIFY EGRESS.
 ALSO, DETAIL 1 ON SHEET A3.20 DOESN'T SPECIFY THE
 HEIGHT OF THE HANDRAIL AND IT LOOKS LIKE THE STAIR
 HANDRAIL PICKETS SPACING DON'T COMPLY WITH THE OPENING
 LIMITATIONS OF SEC. R312.1.3 FBC-RESIDENTIAL.
  
 6- OK.
 7- OK.
 8- OK.
  
 ORIGINAL COMMENT:
 9- PLANS DON'T PROVIDE ANY DETAILS/SPECIFICATIONS FOR
 THE CONSTRUCTION AND INSTALLATION OF NEW CANVAS AWNINGS
 AS SHOWN ON THE EAST ELEVATION. PROVIDE COMPLETE
 DETAILS/SPECIFICATIONS. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 TYPICAL AWING DETAIL ON SHEET A3.20 DOESN'T PROVIDE
 FASTENING SPECIFICATIONS. DESIGNER OF RECORD TO PROVIDE
 THE INFORMATION TO SHOW COMPLIANCE WITH WIND DESIGN.
 SEC. R301.2.1 FBC-RESIDENTIAL.
  
 10- OK.
 11- OK.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF THE
 REVISION MADE WILL HELP TO EXPEDITE THE AUDIT PROCESS.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,