Plan Review Notes
Plan Review Notes For Permit 21101362
Permit Number 21101362
Review Stop P
Sequence Number 1
Notes
Date Text
2021-12-06 18:10:091ST REVIEW FBC-2020 PLUMBING
 PERMIT- 21101362
 12/6/2021
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET AD2.1.1: PLEASE SUBMIT THE INTERIOR PLUMBING
 DEMOLITION PLANS FOR THE PROJECT- SECTION 107.2.1 WPB.
 THE NOTE ON THE PLAN INDICATES UNDER SEPARATE PERMIT
 HOWEVER A PLUMBING REVIEW WAS NOT PERFORMED UNDER
 PERMIT- 21080441.
  
 2) AD2.1.1- PLUMBING DEMO NOTE 1:
 A) UTILITY RELEASE - CITY OF WEST PALM BEACH WATER
 DEPARTMENT, REQUEST FOR METER PULL, ON THEIR FORM
 "DEMOLITION APPLICATION" PLEASE *FAX THE COMPLETED
 "DEMOLITION APPLICATION" FORM TO 561-822-2183.
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
 B) IF A WATER TRUCK IS DESIRED FOR WATERING DOWN SITE,
 DETAILS WILL BE REQUIRED.
 IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED,
 THEN A PARTIAL RELEASE WILL BE NOTED ON THEIR FORM.
 C) KEY NOTE DE27: PLEASE NOTE THAT A SEPARATE PERMIT IS
 REQUIRED FOR REMOVAL OF THE BACKFLOW PREVENTER DEVICE
 AT THE PROPERTY. REPLACEMENT OF THE BACKFLOW WILL ALSO
 REQUIRE A SEPARATE PERMIT. PLEASE PLACE NOTES ON THE
 PLAN FOR CLARIFICATION. FOR FURTHER INFORMATION ABOUT
 THE BACKFLOW PREVENTER PLEASE CONTACT THE UTILITIES
 DEPT. AT 561-822-2244.
  
 3) LS.1.1: PROVIDE PLUMBING FIXTURE CALCULATIONS FOR
 RETAIL SPACES 112 & 113 (M), AND THE FUTURE KITCHEN AND
 RESTAURANT (A2)- SEE TABLE 403.1 FBC P. PLEASE OUTLINE
 THE RESTAURANT AREA AND PROVIDE THE OCCUPANCY
 CLASSIFICATION AND OCCUPANT LOAD. PLEASE SHOW THE
 FIXTURE LOCATIONS ON THE PLANS FOR THESE TENANT SPACES.
  
 4) LS.3.1: PLEASE LABEL THE FIXTURE REQUIREMENTS AS
 THIRD FLOOR INSTEAD OF SECOND FLOOR- SECTION 107.2.1
 WPB.
  
 5) A9.0.1: DETAIL A- FBC ACC MISSING DETAILS AND
 CORRECTIONS.
 A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 WATER CLOSETS- SECTION 604.3.
 B) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 LAVATORIES- 606.2.
 C) TURNING SPACE DIAMETERS- SECTION 304.3.
 D) THE DOORS SHALL NOT SWING INTO THE CLEAR FLOOR
 SPACES FOR THE LAVATORIES- 603.2.3.
  
 6) A9.0.1 DETAILS 2 & 8: PLEASE SHOW THE LENGTHS OF THE
 SIDE GRAB BARS AS DEPICTED IN FIGURE 604.5.1.
  
 7) A9.0.1 DETAILS 1 & 5: PLEASE SHOW THE LENGTHS OF THE
 REAR GRAB BARS AS DEPICTED IN FIGURE 604.5.2.
  
 8) A9.0.1 DETAILS 1 & 5: PLEASE SHOW THE HEIGHTS OF THE
 MIRRORS FROM THE FINISHED FLOORS TO THE REFLECTIVE
 SURFACES- 603.3.
  
 9) A9.0.1 DETAILS 1 & 5: PLEASE RELOCATE THE WATER
 CLOSET FLUSH CONTROLS TO THE OPEN SIDES OF THE
 FIXTURES- 604.6.
  
 10) A9.0.1: SHOW THE KNEE AND TOE CLEARANCES FOR THE
 LAVATORIES IN RR 116 & RR 117- 606.2.
  
 11) A9.0.1 DETAIL B- FBC ACC MISSING DETAILS AND
 CORRECTIONS.
 A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 WATER CLOSETS- SECTION 604.3.
 B) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 LAVATORIES- 606.2.
 C) TURNING SPACE DIAMETERS- SECTION 304.3.
  
 12) A9.0.2 DETAIL A- FBC ACC MISSING DETAILS AND
 CORRECTIONS.
 A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 WATER CLOSETS- SECTION 604.3.
 B) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 LAVATORIES- 606.2.
 C) TURNING SPACE DIAMETERS- SECTION 304.3.
 D) THE DOORS SHALL NOT SWING INTO THE CLEAR FLOOR
 SPACES FOR THE LAVATORIES- 603.2.3.
  
 12) A9.0.2- DETAILS 4 & 6: PLEASE SHOW THE LENGTHS OF
 THE SIDE GRAB BARS AS SPECIFIED IN FIGURE 604.5.1- FBC
 ACC.
  
 13) A9.0.2- DETAILS 3 & 5: PLEASE SHOW THE LENGTHS OF
 THE REAR GRAB BARS AS SPECIFIED IN FIGURE 604.5 FBC
 ACC.
  
 14) A9.0.2- DETAILS 1 & 5: PLEASE SHOW THE HEIGHTS OF
 THE MIRRORS FROM THE FINISHED FLOORS TO THE REFLECTIVE
 SURFACES- 603.3 FBC ACC.
  
 15) A9.02- DETAILS 6, 10, 12: SHOW THE CENTERLINES OF
 THE TOILET PAPER DISPENSERS MEASURED FROM THE FRONTS OF
 THE WATER CLOSETS- SECTION AND FIGURE 604.7 FBC ACC.
  
 16) A9.0.2- DETAILS 8, 13, & 16: SHOW THE KNEE AND TOE
 CLEARANCES FOR THE LAVATORIES- 606.2 FBC ACC.
  
 17) A9.02: PLEASE CLARIFY IF THE URINAL IS INTENDED TO
 BE ACCESSIBLE AND PROVIDE COMPLIANCE DETAILS- CLEAR
 FLOOR SPACE DIAGRAM AND DIMENSIONS, RIM HEIGHT- 605.2 &
 605.3 FBC ACC.
  
 18) A9.02 DETAIL A: THE 4'-1" LENGTH OF THE WOMEN'S
 STANDARD TOILET STALL IS NOT IN COMPLIANCE. MINIMUM 56"
 LENGTH REQUIRED FOR WALL HUNG WATER CLOSET STALLS-
 SECTION 405.3.1 FBC P.
  
 19) A9.03 DETAIL 6- PLEASE SHOW THE LENGTHS OF THE SIDE
 GRAB BARS A DEPICTED IN FIGURE 604.5.1- FBC ACC.
  
 20) A9.03 DETAIL 6: SHOW THE CENTERLINE OF THE TOILET
 PAPER DISPENSER MEASURED FROM THE FRONTS OF THE WATER
 CLOSETS- SECTION AND FIGURE 604.7 FBC ACC.
  
 21) A9.0.3- DETAILS 8, 9, & 11: SHOW THE KNEE AND TOE
 CLEARANCES FOR THE LAVATORIES- 606.2 FBC ACC.
  
 22) A10.2.1- DETAIL 1: SHOW THE DEPTH OF THE SINK
 COUNTER- 308.1 FBC ACC.
  
 23) A10.2.1- DETAIL 1: SHOW THE MAXIMUM 25 INCHES
 MAXIMUM KNEE CLEARANCE- 306.3 FBC ACC.
  
 24) A10.2.1 DETAIL 1: SHOW THE MINIMUM 11-INCH KNEE
 CLEARANCE AT 9 INCHES ABOVE THE FINISHED FLOOR, AND 8
 INCHES DEEP MINIMUM AT 27 INCHES ABOVE THE FLOOR- 306.3
 FBC ACC.
  
 25) P1.0: CIVIL DRAWINGS ARE REFERENCED IN THE KEY
 NOTES HOWEVER THE DRAWINGS WERE NOT PROVIDED- SECTION
 107.2.1 WPB.
  
 26) P1.0, P5.2, & P5.3: PLEASE IDENTIFY OR LABEL THE
 GREASE INTERCEPTORS AND SOLIDS INTERCEPTORS ON P5.2 &
 P5.3 TO CORRELATE WITH THE PLUMBING PLAN LABELS WHICH
 ARE GL-1, GL-2, SL-1, SL-2- SECTION 107.2.1 WPB.
  
 26) P1.0, P5.2 & P5.3: PLEASE PLACE A NOTE ON THE PLAN
 TO INDICATE SEPARATE PERMITS ARE REQUIRED FOR THE
 INTERCEPTORS- SECTIONS 105.1 & 107.2.1 WPB.
  
 27) P1.0 & P.5.3: THE GREASE INTERCEPTOR CALCULATIONS
 INDICATE EXISTING TENANT, HOWEVER THE PLAN SHOWS TWO
 NEW TENANT SPACES. PLEASE PROVIDE CALCULATIONS FOR EACH
 NEW TENANT SPACE. PLEASE NOTE THE SPACES ARE IDENTIFIED
 AS RETAIL 112 & 113.
  
 28) P1.0 & P.5.3: SHOW THE LOCATION OF THE SAMPLING
 PORT FOR GL-2- SECTION 1003.3.5 FBC P.
  
 29) P1.0 KEYNOTE 2: INDICATE THE MAXIMUM DEVELOPED
 LENGTH IN FEET OF THE SYSTEM- TABLE E201.1 FBC P.
  
 30) P1.0 KEYNOTE 19: PLEASE INDICATE THE DISCHARGE
 LOCATION OF THE SUMP LINE- 712.3.5 FBC P.
  
 31) P1.0 KEYNOTES 20, 21, & 22: PLEASE REFER TO COMMENT
 #1.
  
 32) P1.0: SHOW THE LOCATION OF KEYNOTE 38 ON THE PLAN-
 SECTION 107.2.1 WPB.
  
 33) P1.0 KEYNOTE 44: PLEASE PROVIDE SUPPORT AND HANGING
 DETAILS FOR INSTALLATION OF THE DRAIN PANS- SECTION
 107.2.1 WPB.
  
 34) P1.0 KEYNOTE 55: INDICATE HOW ACCESS WILL BE
 PROVIDED FOR THE BACKWATER VALVE- SECTION 714.3 FBC P.
  
 35) P1.0: PLEASE PROVIDE ENLARGED PIPING DRAWINGS FOR
 THE NEW ACCESSIBLE RESTROOMS 116 & 117- SECTION 107.2.1
 WPB.
  
 36) P2.0 KEYNOTE 22: PLEASE PROVIDE ADDITIONAL
 INFORMATION FOR THE SUMP LINE IN THE MECH CHASE. IS THE
 CHASE A FIRE-RATED SHAFT OR PLENUM ENCLOSURE? PLEASE
 NOTE THAT PVC PIPE IS COMBUSTIBLE MATERIAL AND MAY BE
 RESTRICTED FROM INSTALLATION IN THE CHASE- SECTION
 602.2.1 FBC M.
  
 37) P4.1: ROOF DRAINAGE:
 A) PLEASE PROVIDE KEYNOTES FOR THE NEW ROOF DRAINS
 (RD-1)- SECTION 107.2.1 WPB.
 B) SHOW THE GPM DRAINAGE FLOW AT EACH NEW AND EXISTING
 DRAIN LOCATION. PLEASE INCLUDE THE EXISTING VERTICAL
 LEADER PIPE SIZES- 1106.1 FBC P.
 C) SHOW THE DRAINAGE SLOPES OF THE ROOF TO THE DRAIN
 LOCATIONS- 1101.7, 1105.1 FBC P.
  
 38) P7.1: INDICATE HOW TEMPERED WATER WILL BE DELIVERED
 FROM THE LAVATORIES- SECTION 419.5 FBC P.
  
 39) P7.2 PLEASE INDICATE THE SIZE AND SLOPE OF THE
 EXISTING SANITARY WASTE PIPE AND THE TOTAL DFU?S OF THE
 SYSTEM- TABLE 710.1(1) FBC P.
  
 40) P7.2: PLEASE PROVIDE A TOTAL DFU CALCULATION THAT
 INCLUDES THE FUTURE FIXTURES ON THE 3RD FLOOR- TABLE
 710.1(1) FBC P.
  
 41) P5.2: PLEASE NOTE THAT THE WPB BUILDING DEPT. DOES
 NOT ALLOW ALL THE USE OF BARRIER-TYPE TRAP SEALS IN
 KITCHEN AREAS OR OTHER AREAS WHERE GREASE, OIL, DEBRIS
 OR OTHER SUBSTANCES ARE COLLECTED AND WHICH MAY CAUSE
 FAILURE OF THE DEVICE- SECTION 1002.4.1.3 FBC P.
  
 42) P5.1: PROVIDE EQUIPMENT SCHEDULES FOR THE NEW WATER
 HEATERS AND THERMAL EXPANSION TANKS AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS AND INSTALLATION MANUALS-
 SECTION 502.1 FBC P.
  
 43) P6.1 & P6.2: PLEASE NOTE THAT MANUFACTURER'S
 SPECIFICATIONS AND INSTALLATION MANUALS FOR ALL
 PLUMBING FIXTURES, APPLIANCES, AND DEVICES SHALL BE
 ONSITE AT TIME OF INSPECTION- SECTION 107.2.1 WPB. IF
 SUBMITTALS ARE TO BE DEFERRED PLEASE PROVIDE A LIST OF
 PRODUCTS ON THE PLAN- SECTION 107.3.4.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved