2021-11-23 16:12:02 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION |
| SERVICES/ BUILDING DIVISION |
| 2020 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 21101014 |
| ADD: 2480 PRESIDENTIAL WAY # 501 |
| CONT: WRIGHT?S IMPACT WINDOW & DOOR LLC |
| TEL: 561-588-7353 |
| E-MAIL: [email protected] |
| |
| 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: TUES. NOV. 23RD/ 2021 |
| ACTION: DENIED |
| |
| 1) DRAWING 1 WRIGHT?S FLOOR PLAN NEEDS TO SHOW WHO THE |
| AUTHOR IS OF THE PLAN. CERTIFICATION BY CONTRACTOR. |
| 107.3.4.3. THE CONTRACTOR (QUALIFIER) THAT CREATED / |
| DREW THE SET OF PLANS WILL NEED TO IDENTIFY THEMSELVES |
| AS THE AUTHOR OF THE PLANS. PLEASE PRINT YOUR NAME, |
| SIGN YOUR NAME AND LICENSE NUMBER FOR THE TRADE YOU ARE |
| LICENSED IN AND PLANS DRAWN. |
| |
| 2) DRAWING 1 WRIGHT?S FLOOR PLAN IT APPEARS IS TRYING |
| TO CREATE A CORNER POST/ COLUMN BY USING (3) 2X5 S, |
| COVER GAP WITH 5/8 INCH PLYWOOD AND WRAP WITH |
| BREAK-METAL. PLEASE NOTE THERE IS NO INFORMATION AS TO |
| WHAT TYPE OF METAL STUDS ARE GOING TO BE USED. |
| ARCHITECTURAL OR STRUCTURAL, GAUGE, SCREW SIZE OR |
| SPACING TO CREATE THE COLUMN, TOP AND BOTTOM PLATES, |
| ANCHORS TO CONCRETE, ANCHORS INTO THE METAL COLUMN, |
| TYPE OF ANCHORS AND SPACING TO SECURE THE PLYWOOD, TYPE |
| OF MATERIAL AND THICKNESS TO SEPARATE THE STEEL SCREWS |
| OF THE SUB SHEATHING AND ALUMINUM BREAK METAL TO STOP |
| ELECTROLYSIS FROM OCCURRING. THIS STRUCTURE NEEDS TO BE |
| ENGINEERED WITH CALCULATIONS FOR THE LATERAL FORCES IT |
| IS GOING TO NEED TO RESIST WITH SAFETY FACTOR. SEE THE |
| DEFINITIONS FOR ENGINEERING 2021 FS 471.005(7). |
| |
| 3) MISSING 2020 FBC-B 1603.1.4 WIND DESIGN DATA. THE |
| FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL BE |
| SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE |
| STRUCTURE: |
| |
| 3.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), |
| MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS |
| DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1. |
| |
| 3.2. RISK CATEGORY. |
| |
| 3.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE |
| THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. |
| HEIGHT AND EXPOSURE. ASCE 7-16 TABLE 30.3.1. |
| |
| 3.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. |
| |
| 3.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR |
| COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED |
| BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR |
| THE DESIGN OF THE STRUCTURE, PSF. |
| |
| 3.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| BUILDING. ASCE 7-10 TABLE 30.3.1. 1609.3.1 WIND SPEED |
| CONVERSION VULT TO VASD. |
| |
| |
| 4) THE FLOOR PLAN STATES THIS IS A 220 FOOT HIGHRISE |
| BUILDING BUT THERE WAS NO ENGINEERING SHEET FOR |
| COMPONENTS AND CLADDING SUBMITTED NOR WHICH WINDOWS AND |
| DOORS ARE IN WALL ZONE 4 AND 5. BUILDING END ZONES (5). |
| THE FLOOR PLAN LAYOUT INDICATES THE WORK TO BE |
| PERFORMED UNDER THIS PERMIT IS A CORNER UNIT OF A |
| HIGHRISE BUILDING. THE WIND LOAD CHART UNDER NOTES |
| STATES WHAT IS CONSIDERED AN END ZONE 10% OF THE LEAST |
| HORIZONTAL DISTANCE OF THE BUILDING OR 40% OF THE MRH, |
| BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DISTANCE |
| OR 3 FT. THE CONTRACTOR HAS NOT IDENTIFIED WHAT THE |
| LEAST HORIZONTAL DISTANCE IS FOR THE BUILDING NOR THE |
| LOCATION OF THE UNIT IN RELATIONSHIP TO THE BUILDING |
| AND THE INTERCOASTAL WATERWAY. EXAMPLE ONLY. IF THE |
| BUILDING HEIGHT IS APPROXIMATELY 180 FT. (MRH.) X 0.40= |
| 72 FEET. THIS WOULD PUT ALL OPENINGS IN WIND ZONE 5 OR |
| 10% OF THE LEAST HORIZONTAL DISTANCE OF THE BUILDING, |
| ALSO UNKNOWN. |
| |
| 5A) THE REVIEW OF THE SUBMITTED PRODUCT APPROVALS CAN |
| NOT OCCUR WITH ALL OF THE UNKNOWNS LISTED IN COMMENT 4 |
| AND 5. |
| |
| 5B) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS |
| WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE |
| 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING (SHOP |
| DRAWING STAMP OF APPROVAL) BY THE DESIGNER OF RECORD |
| PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| |
| 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS |
| REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT |
| REVIEW CYCLE. |
| |
| |
| AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE WORKING |
| FROM CITY HALL. |
| MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM |
| PART-TIME/ RETIRED. |
| |
| IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET |
| BACK INTO THE OFFICE CALL |
| (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. |
| THANK YOU. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| DEPARTMENT |