Plan Review Notes
Plan Review Notes For Permit 21100652
Permit Number 21100652
Review Stop M
Sequence Number 1
Notes
Date Text
2021-11-05 13:18:451ST REVIEW FBC-2020 MECHANICAL
 PERMIT-21100652
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE
 FBC M- FLORIDA MECHANICAL CODE
 FBC EC- FLORIDA ENERGY CONSERVATION
 FBC FG- FLORIDA FUEL GAS
 FBC EX- FLORIDA EXISTING BUILDING CODE
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE MECHANICAL EQUIPMENT SIZING
 CALCULATIONS. FBC EC C403.2.1
  
 2) PLEASE PROVIDE A MECHANICAL DRAWING SHOWING THE
 LOCATION OF THE CONDENSING UNITS. FBC 107.2.1
  
 3) PLEASE PROVIDE A DRAWING SHOWING THE CONDENSATE
 TERMINATION LOCATION, WHERE DOES THE SUMP PIT DRAIN TO?
 FBC M 307
  
 4) WHAT IS THE REASON FOR THE EXHAUST FAN?
  
 5) PLEASE SHOW THE LOCATION OF THE EXHAUST FAN
 TERMINATION LOCATION. FBC M 501.3.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy