2021-12-29 11:04:14RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21100553
  
 NOTE:
 ADDITION SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 NOTE:
 CHANGE OF OCCUPANCY (GARAGE CONVERSION)SEC. 605 AND
 SEC. 1001.2.1, SEC. 604 AND SEC. 901.2, SEC. 801.3
 FBC-EXISTING BUILDING. ALL NEW WORK SHALL COMPLY WITH
 THE MATERIALS AND METHODS REQUIREMENTS IN THE FLORIDA
 BUILDING CODE.
  
 1- THERE ARE TWO SEPARATE STRUCTURES IN THIS PROPERTY.
 A PERMIT APPLICATION IS REQUIRED FOR EACH STRUCTURE.
 PLEASE SUBMIT A SEPARATE PERMIT APPLICATION FOR THE
 SEPARATE GARAGE/GUEST SUITE BUILDING. SAME PLANS CAN BE
 USED. SEPARATE PERMIT APPLICATIONS HELP TO COORDINATE
 INSPECTIONS FOR EACH BUILDING AND TO FACILITATE RECORDS
 RETENTION. SEC. 107.2.1.3 CITY AMENDMENTS.
  
 2- LOT DRAINAGE
 PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE
 FOLLOWING: R401.3 FBC-RESIDENTIAL. SEC. 107.2.5 CITY
 AMENDMENTS.
 SEC. 110.9 CITY AMENDMENTS.
 NOTE: DRAINAGE PLAN TO SHOW THE EXISTING AND PROPOSED
 GRADE ELEVATIONS SHOWING HOW KEEPING WATER AWAY FROM
 ADJACENT PROPERTIES.
  
 3- GARAGE CONVERSION. ENTRY DOOR DOESN'T COMPLY WITH
 THE MIN. CLEAR WIDTH OF 32" AS REQUIRED BY SEC. R311.2
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 4- REVISE DESIGN CRITERIA ON SHEET S.0. FBC 2020 HAS
 ADOPTED THE ASCE 7-16 NOT 7-10.
 ALSO, REVISE THE PROJECT DATA INFORMATION ON SHEET T1.
 FBC-2020 IS THE 7TH EDITION NOT THE 6TH EDITION. SEC.
 553 F.S.
  
 5- PROVIDE STRUCTURAL BUCK DETAIL FOR ALL DOOR TYPES
 AND WINDOWS SHOWING COMPLIANCE WITH SEC. R609.7.2.1
 FBC-RESIDENTIAL. SPECIFY STRUCTURAL BUCK SIZE AND
 FASTENING.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR/WINDOW FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 6- SHEET S.2:
 A)REVISE ROOF PLAN NOTE #1: REVISE PLYWOOD ROOF
 SHEATHING NAILING SPACING. ROOF SHEATHING NEEDS TO BE
 NAILED WITH RING SHANK NAILS AT 4 INCHES O.C. IN THE
 FIELD AND EDGES AS REQUIRED BY SEC. R803.2.3.1 AND
 TABLE R803.2.3.1 FBC-RESIDENTIAL.
 NOTE: REVISE ALL NOTES REFERENCING THE ROOF SHEATHING
 THICKNESS AND NAIL SIZE/ SPACING SHOWN ON DRAWINGS
 SUBMITTED TO AVOID CONFLICTS/DELAYS.
  
 B)REVISE EDGE DISTANCE "A" SHOWN ON THE ROOF DIAGRAMS.
 DIMENSION FOR "A" NEEDS TO BE 4'-0" MIN. ON ALL CASES
 AS REQUIRED BY NOTE ON FIGURE R301.2(7).
  
 7- ROOFING:
 A)PROVIDE SPECIFICATIONS SHOWING HOW COMPLYING WITH THE
 NEW 2020 CODE REQUIREMENT FOR ROOFING UNDERLAYMENT.
 SEC. R905.1.1.1 FBC-RESIDENTIAL.
 NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1
 FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE
 PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001
  
 B)SPECIFY SHINGLES ROOF PITCH. NEED TO VERIFY
 COMPLIANCE WITH SEC. R905.2.2 FBC-RESIDENTIAL.
  
 8- ENERGY CALCULATIONS:
 A)NEED A SEPARATE PERMIT APPLICATION FOR EACH SEPARATE
 STRUCTURE.
 SEC. R101.3 FBC-ENERGY CONSERVATION. SEC.
 R101.5FBC-ENERGY CONSERVATION.
 NOTE: GARAGE ENERGY CALCULATIONS NEED TO BE FOR ENTIRE
 BUILDING (EXISTING AND ADDITION) SINCE IT WAS NOT A/C
 BEFORE.
  
 B)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME AND BUILDER'S NAME.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 C)ITEM #5 ON PAGE 1 SPECIFIES NO WORST CASE SCENARIO,
 WHILE PAGE 2 SHOWS A ROTATION OF 270 DEGREES. ENERGY
 CALCULATIONS NEED TO BE SITE SPECIFIC AS REQUIRED BY
 SEC. R405.4.2.1 (4) FBC- ENERGY CONSERVATION. REVISE AS
 REQUIRED.
  
 D)REVISE WINDOWS ORIENTATION, AREA AND OVERHANG DEPTH
 AND SEPARATION TO MATCH PLANS. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 9-DEFERRED SUBMITTAL: PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE:ALL PRODUCT APPROVALS TO BE APPROVED IN WRITING
 BY DESIGNER OF RECORD PRIOR TO SUBMITTAL):
 A)EXTERIOR DOORS.
 B)WINDOWS.
 C)WINDOW MULLIONS (NOTE: NEED TO SPECIFY MULLION SIZE
 TO AVOID DELAYS/CONFLICTS).
 D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 E)ROOF SHINGLES.
 F)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,