2022-01-24 15:49:08 | RESIDENTIAL(R3) ALTERATION, SECOND BUILDING REVIEW |
| COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #21091316 |
| |
| NOTE: |
| LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING. |
| SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL |
| COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN |
| THE FLORIDA BUILDING CODE. |
| |
| COPY OF ORIGINAL COMMENT FROM PREVIOUS PLAN EXAMINER: |
| 1. FBC 107, FBC EB 702.4, REVISE PLAN TO PROVIDE THE |
| FOLLOWING INFORMATION: |
| ROOM DESIGNATION (FOR INSTANCE, BEDROOM, KITCHEN, ETC.) |
| TYPE OF WINDOW CURRENTLY IN THE OPENING |
| TYPE OF WINDOW PROPOSED |
| |
| RESPONSE: |
| REPEAT COMMENT. REVISED PLAN DOESN'T PROVIDE THE |
| REQUIRED INFORMATION: |
| |
| WINDOW REPLACEMENT |
| A)PROVIDE FLOOR PLAN OR SKETCH IDENTIFYING THE ROOMS |
| WHERE WINDOWS ARE GOING TO BE REPLACED. FOR EXAMPLE: |
| BEDROOM, LIVING AREA, ETC. THIS IS REQUIRED TO IDENTIFY |
| THE BEDROOMS AND VERIFY COMPLIANCE WITH THE EGRESS |
| REQUIREMENTS. SEE COMMENT #2 BELOW. SEC. 107.2.1 CITY |
| AMENDMENTS. |
| |
| B)SPECIFY SIZE AND TYPE OF EXISTING WINDOW AND SIZE AND |
| TYPE OF PROPOSED WINDOWS TO VERIFY COMPLIANCE WITH THE |
| EGRESS REQUIREMENTS OF SEC. 702.5 FBC-EXISTING |
| BUILDING. |
| |
| ADDITIONAL COMMENT TO BE CONSIDERED: |
| 2-SECOND FLOOR WINDOW OPENING CONTROL DEVICES: WINDOW |
| OPENING CONTROL DEVICES IN WINDOW REPLACEMENT ARE |
| REQUIRED WHEN THE TOP SILL OF THE WINDOW OPENING IS AT |
| A HEIGHT LESS THAN 24 INCHES (610 MM) ABOVE THE |
| FINISHED FLOOR. |
| WINDOW OPENING CONTROL DEVICES NEED TO COMPLY WITH ASTM |
| F2090. |
| CLEARLY SPECIFY IF THERE ARE ANY WINDOWS WHERE THE |
| WINDOW SILL IS LESS THAN 24" ABOVE THE FINISH FLOOR. |
| SEE SEC. 702.4 FBC-EXISTING BUILDING CODE. |
| NOTE: THIS SECTION ALSO APPLIES TO OPERABLE WINDOWS |
| WHERE WINDOW SILL IS GREATER THAN 72 INCHES ABOVE GRADE |
| OR OTHER SURFACE BELOW. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |