2021-12-16 14:50:06PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING - COMMENTS FROM THE FIRST REVIEW
 WERE NOT CORRECTED.
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT A ROOF DIAGRAM WITH DIMENSIONS, ROOF SLOPES
 AND MEAN ROOF HEIGHT SPECIFIED. SHOW GABLES AND HIPS.
 FBC AMENDMENTS 107.2.1
  
 2) SHOW THAT THE VALUE OF THE STRUCTURE IS LESS THAN
 $300,000.00 OR SPECIFY HOW THE ROOF TO WALL CONNECTIONS
 WILL BE IMPROVED. FBC EXISTING BUILDING 706.8
  
 3) THE POLYSTICK TU MAX THAT IS SPECIFIED IN THE
 PRODUCT APPROVAL FOR THE UNDERLAYMENTS IS NOT AN
 ALLOWABLE UNDERLAYMENT FOR ASPHALT SHINGLES PER TABLE 1
 ON PAGE 5 OF THE PRODUCT APPROVAL. SELECT AN
 APPROPRIATE UNDERLAYMENT. FBC AMENDMENTS 107.2.1