Plan Review Notes For Permit 21090861 |
Permit Number |
21090861 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2022-03-23 13:04:20 | CANOPY | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE THE SOIL REPORT AS REFERENCED ON | | DRAWING F1. | | | | 2) WIND DESIGN DATA SHOWN ON THE DRAWINGS AND THE | | CALCULATIONS SHOWS - RISK CATEGORY II WITH A WIND SPEED | | OF 168 - MINIMUM WIND SPEED FOR A RISK CATEGORY II IS | | 170MPH PER FBC WPB SECTION 120. | | | | |
|