2021-12-07 07:30:13MISSING THE WIND DESIGN CRITERIA FOR MID-RISE
 CONDOMINIUM. PLEASE NOTE A FORM FROM WELLINGTON IS FOR
 THE ADDRESS 14224 ASTER AVE. WELLINGTON. THIS FORM
 STATES IT IS LIMITED TO BUILDINGS TO A HEIGHT OF 30
 FEET. THIS IS A FOUR STORY BUILDING AND HEIGHT OF THE
 BUILDING IS TAKEN AT THE MEAN ROOF HEIGHT. THE VERTICAL
 DISTANCE FROM GRADE PLANE TO THE AVERAGE HEIGHT OF THE
 HIGHEST ROOF SURFACE.
 PROVIDE A SIGNED AND SEALED ENGINEERING SHEET FOR WIND
 PRESSURES. 1ST REVIEW. CONTRACTORS CAN ONLY PROVIDE
 PRESSURES FOR A ONE- & TWO-FAMILY DWELLING FROM THE
 2020 RESIDENTIAL CODE TABLE R301.2(2).
  
  