Plan Review Notes
Plan Review Notes For Permit 21090359
Permit Number 21090359
Review Stop P
Sequence Number 1
Notes
Date Text
2021-09-28 12:36:51CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 21090359 801 S OLIVE AVE 104
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 1.PER WPB FBC 104.1, A PLUMBING SUB-PERMIT APPLICATION
 SHALL BE SUBMITTED FOR THIS PROJECT BY A LICENSED
 PLUMBING CONTRACTOR.
  
 2.PER WPB FBC 107.2.1, A PLUMBING PLAN IS REQUIRED.
 ?A) IF THE PLANS ARE NOT SIGNED AND SEALED BY A
 PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN
 IN ACCORDANCE WITH WPB FBC 107.3.4.3 SHALL BEAR THE
 PRINTED NAME, THE SIGNATURE AND THE CERTIFICATION
 NUMBER OF THE DESIGNER WHO SHALL BE A CONTRACTOR
 LICENSED IN THE PLUMBING TRADE (SAID PLAN/PLANS MAY BE
 A COPY OF THE ORIGINAL SUBMITTED PLANS TITLED PLUMBING
 FIRST FLOOR/PLUMBING SECOND FLOOR). PLEASE NOTE THAT
 WHEN SCANNED DRAWINGS ARE SUBMITTED WITH CONTRACTOR'S
 PRINTED NAME, SIGNATURE AND LICENSE NUMBER IN
 ACCORDANCE WITH WPB FBC 107.3.4.3, A PAPER PLAN WITH
 WET SIGNATURE SHALL BE PROVIDED TO THE BUILDING
 DEPARTMENT FOR HARD RECORD FILE PRIOR TO ISSUANCE OF A
 PERMIT.
 ?B) PER WPB FBC 107.2.1, PROVIDE AN EXISTING FLOOR PLAN
 AND A PROPOSED FLOOR PLAN. CLEARLY INDICATE THE
 PLUMBING SCOPE AND ANY CHANGES FROM THE EXISTING TO THE
 PROPOSED.
 ?C) PER WPB FBC 107.2.1, PROVIDE SHOWER PAN AND CURB
 DETAIL PROVIDING THE FOLLOWING REQUIREMENTS NOTED IN
 FBC PL 421.5.2. LINER SHALL TURN UP ON ALL SIDES NOT
 LESS THAN 2 INCHES (51 MM) ABOVE THE FINISHED THRESHOLD
 LEVEL. LINERS SHALL BE RECESSED AND FASTENED TO AN
 APPROVED BACKING SO AS NOT TO OCCUPY THE SPACE REQUIRED
 FOR WALL COVERING, AND SHALL NOT BE NAILED OR
 PERFORATED AT ANY POINT LESS THAN 1 INCH (25 MM) ABOVE
 THE FINISHED THRESHOLD. LINERS SHALL BE PITCHED
 ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL
 (2-PERCENT SLOPE) AND SHALL BE SLOPED TOWARD THE
 FIXTURE DRAIN AND BE SECURELY FASTENED TO THE WASTE
 OUTLET AT THE SEEPAGE ENTRANCE, MAKING A WATER-TIGHT
 JOINT BETWEEN THE LINER AND THE OUTLET.
 ??C1)SPECIFY ON THE DETAIL THE LINER MATERIAL SHOWING
 COMPLIANCE WITH ONE OF THE FOLLOWING; FBC PL 421.5.2.1,
 421.5.2.2, 421.5.2.3, 421.5.2.4, 421.5.2.5, 421.5.2.6.
 ??C2)INDICATE ON THE DETAIL THE TYPE OF FLOOR (I.E.,
 STRUCTURAL CONCRETE, CONCRETE WITH POST TENSION, WOOD,
 ETC.) THE SHOWER COMPARTMENT WILL BE LAID ON TO SHOW
 COMPLIANCE WITH FBC PL 421.5.1.
 ?D) PER WPB FBC 107.2.1, SHOW COMPLIANCE WITH FBC PL
 421.4.1 BATHTUB FLOORS, SHOWER FLOORS, WALL AREAS ABOVE
 BUILT-IN TUBS THAT HAVE INSTALLED SHOWER HEADS AND
 WALLS IN SHOWER COMPARTMENTS SHALL BE CONSTRUCTED OF
 SMOOTH, CORROSION-RESISTANT AND NONABSORBENT WATERPROOF
 MATERIALS. WALL MATERIALS SHALL EXTEND TO A HEIGHT OF
 NOT LESS THAN 6 FEET (1829 MM) ABOVE THE ROOM FLOOR
 LEVEL, AND NOT LESS THAN 70 INCHES (1778 MM) ABOVE THE
 DRAIN OF THE TUB OR SHOWER. SUCH WALLS SHALL FORM A
 WATER-TIGHT JOINT WITH EACH OTHER AND WITH EITHER THE
 TUB OR SHOWER FLOOR.
 ?E)PER WPB FBC 107.2.1, PROVIDE NOTE STATING ?PER FBC
 PL412.3, INDIVIDUAL SHOWER AND TUB-SHOWER COMBINATION
 VALVES SHALL BE BALANCED-PRESSURE, THERMOSTATIC OR
 COMBINATION BALANCED-PRESSURE/THERMOSTATIC VALVES THAT
 CONFORM TO THE REQUIREMENTS OF ASSE 1016/ASME
 A112.1016/CSA B125.16 OR ASME A112.18.1/CSA B125.1 AND
 SHALL BE INSTALLED AT THE POINT OF USE."
  
 3.SUPPORTING DOCUMENT TITLED SITE LOCATION APPEARS TO
 BE THE FIRST FLOOR/DOWNSTAIRS FLOOR PLAN; SUPPORTING
 DOCUMENT TITLED SITE PLAN APPEARS TO BE THE SECOND
 FLOOR/UPSTAIRS FLOOR PLAN. PER WPB FBC 107.2.1,
 CLARIFY. IT WOULD BE HELPFUL TO NAME THE DOCUMENTS AS
 SUCH AND WHEN RESUBMITTING, UPLOAD THEM TO THE DRAWINGS
 FOLDER.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
 21090359 801 S OLIVE AVE 104
  