Plan Review Notes For Permit 21090106
Permit Number 21090106
Review Stop P
Sequence Number 1
Notes
Date Text
2021-09-24 10:34:311ST REVIEW FBC-2020 RES. PLUMING
 PERMIT- 21090106
 9/24/21
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) P2: THE LOCATION OF THE RPZ BACKFLOW PREVENTER IS
 NOT IN COMPLIANCE WITH THE WPB UTILITIES CROSS
 CONNECTION MANUAL. THE DEVICE SHALL BE INSTALLED
 IMMEDIATELY BEYOND THE WATER METER. PLEASE REVISE THE
 PLAN AND NOTE THAT A SEPARATE PERMIT IS REQUIRED FOR
 INSTALLATION OF THE BACKFLOW PREVENTER.
  
 PLEASE NOTE THAT A FL. LICENSED PLUMBING CONTRACTOR
 SHALL OBTAIN A SEPARATE PERMIT FOR INSTALLATION OF THE
 BACKFLOW PREVENTER IN ACCORDANCE WITH SECTION 105.1 WPB
 AND SEC. 90-33 WPB CODE OF ORDINANCES. THE DEVICE SHALL
 BE TESTED AND CERTIFIED BY THE WPB UTILITIES DEPARTMENT
 PRIOR TO FINAL INSPECTION BY THE BUILDING DEPARTMENT.
 PLEASE CONTACT THE WPB UTILITIES CENTRAL OPERATIONS
 DEPT.AT 561-822-2210 FOR FURTHER INFORMATION.
  
 2) P-4: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW WATER
 HEATER INDICATING THE MAKE AND MODEL AND EFFICIENCY
 RATING- TABLE C404.1 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  