Date |
Text |
2021-09-10 17:20:56 | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW |
| COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #21081335 |
| |
| NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| SHALL COMPLY WITH THE MATERIALS AND METHODS |
| REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| |
| 1- NEW MODIFIED BITUMEN FLORIDA PRODUCT APPROVAL |
| FL16709-R8 SUBMITTED: |
| A) BUILDING EXPOSURE: ACCORDING TO SEC. R301.2.1.4 |
| FBC-RESIDENTIAL THIS BUILDING IS LOCATED IN EXPOSURE |
| "D" NOT "C". REVISE AS REQUIRED. |
| |
| B) PAGE 25 OF 25 OF MODIFIED BITUMEN FLORIDA PRODUCT |
| APPROVAL FL16709-R8 SUBMITTED INDICATES "N/A " FOR ROOF |
| ZONE 3 FOR AN ULTIMATE WIND SPEED OF 170MPH IN BUILDING |
| EXPOSURE D. |
| "N/A" INDICATES THE SYSTEM CANNOT BE USED WITHIN THE |
| PRESSURE ZONE. SEE MEANING OF "N/A" ON PAGE 22 OF 25 |
| UNDER TABLE 7 HEADING. |
| NEED TO USE ANOTHER PRODUCT APPROVAL OR PROVIDE SINGED |
| AND SEALED RAS 117 CALCULATIONS FOR PRODUCT APPROVAL FL |
| 2533-R5 AS REQUESTED ON THE FIRST REVIEW. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |
| |
| ************************************** |
| ORIGINAL REVIEW COMMENTS: |
| |
| PLAN REVIEW ROOFING |
| |
| CHRISTOPHER S. THROOP, C.B.O., CFM |
| PLANS EXAMINER II PX3169/RPX306 |
| INSPECTOR BN4338 |
| BUILDING OFFICIAL BU1635 |
| ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935 |
| DEVELOPMENT SERVICES DEPARTMENT |
| CITY OF WEST PALM BEACH |
| (561) 805-6726 |
| [email protected] |
| |
| CODES IN EFFECT: |
| 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| 2017 NEC |
| |
| 1ST REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. PROVIDE ENHANCED FASTENER CALCULATIONS PER |
| LIMITATIONS NOTE 5.7.2 OF FL 2533-R5, PREPARED BY A |
| QUALIFIED DESIGN PROFESSIONAL. |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |