2021-09-29 08:05:031ST REVIEW FBC-2020 RES. BUILDING.
 PERMIT- 21081335
 9/20/21
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE SLOPE OF THE ROOF AND THE MEAN ROOF
 HEIGHT ON THE SKETCH. A COMPLETE REVIEW OF THE TILE
 ROOF CANNOT BE COMPLETED WITHOUT THIS INFORMATION-
 SECTION R905.3 FBC RES, FAC RULE 9N-3, FRSA HIGH WIND
 CONCRETE AND TILE INSTALLATION MANUAL- 6TH EDITION. THE
 ROOF APPEARS TO BE IN AN EXPOSURE C LOCATION. REFER TO
 FRSA TABLES 2HC FOR DESIGN PRESSURE LIMITATIONS.
  
 2) MIAMI-DADE NOA #18-0502.03- TILE SEAL: UNDER
 LIMITATION #9 ON PAGE 4, BORAL TILE SEAL MUST BE
 SPECIFICALLY LISTED IN THE ROOF TILE NOA AS A COMPONENT
 PART OF AN ASSEMBLY. THE SUBMITTED NOA FOR THE TILE-
 19-1021.3 DOES NOT LIST THE UNDERLAYMENT.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 BUILDING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  