Plan Review Notes For Permit 21081110
Permit Number 21081110
Review Stop B
Sequence Number 1
Notes
Date Text
2021-09-01 17:39:59WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 21081110
 ADD: 7106 S. DIXIE HWY.
 CONT: CAMPBELL GENERAL CONTRACTING
 TEL: 772-486-3764
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. SEPT. 01/2021
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION DOES NOT INDICATE IF THIS
 STRUCTURE IS TO BE CONSIDERED TEMPORARY IN NATURE OR TO
 BE CONSIDERED A PERMANENT STRUCTURE. 2020 WEST PALM
 BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER
 1, ADMINISTRATION SECTION 108.1. THE BUILDING OFFICIAL
 IS AUTHORIZED TO ISSUE A PERMIT FOR TEMPORARY
 STRUCTURES AND TEMPORARY USES. SUCH PERMITS SHALL BE
 LIMITED AS TO TIME OF SERVICE BUT SHALL NOT BE
 PERMITTED FOR MORE THAN 6 MONTHS. THE BUILDING OFFICIAL
 IS AUTHORIZED TO GRANT EXTENSIONS FOR DEMONSTRATED
 CAUSE.
  
 108.2 CONFORMANCE. TEMPORARY STRUCTURES AND USES SHALL
 CONFORM TO THE STRUCTURAL STRENGTH, FIRE SAFETY, MEANS
 OF EGRESS, ACCESSIBILITY, LIGHT. VENTILATION AND
 SANITARY REQUIREMENTS OF THIS CODE AS NECESSARY TO
 ENSURE PUBLIC HEALTH, SAFETY AND GENERAL WELFARE.
  
 2) IF THE STRUCTURE IS GOING TO BE PERMANENT THEN THE
 STRUCTURE WILL NEED TO SHOW COMPLIANCE WITH 108.2
 CONFORMANCE. PERMANENT STRUCTURES AND USES SHALL
 CONFORM TO THE STRUCTURAL STRENGTH, FIRE SAFETY, MEANS
 OF EGRESS, ACCESSIBILITY, LIGHT. VENTILATION AND
 SANITARY REQUIREMENTS OF THIS CODE AS NECESSARY TO
 ENSURE PUBLIC HEALTH, SAFETY AND GENERAL WELFARE.
  
 3) A STRUCTURAL ENGINEER WILL NEED TO ENGINEER AND OR
 CALCULATE ANCHORAGE OF THIS UNIT IN CONFORMANCE WITH
 THE 2020
 FBC-BUILDING SECTION 1604.8 ANCHORAGE. BUILDINGS AND
 OTHER STRUCTURE, AND PORTIONS THEREOF, SHALL BE
 PROVIDED WITH ANCHORAGE IN ACCORDANCE WITH SECTIONS
 1604.8.1 THROUGH 1604.8.3 AS APPLICABLE. PERMANENT
 BUILDINGS HAVE FOUNDATIONS, SEE 1809.4 DEPTH AND WIDTH
 OF FOUNDATIONS.
  
 4) THE ENGINEER WILL HAVE TO ENGINEER THE ANCHORAGE TO
 THE PROPER WIND ZONE TO KEEP THE STRUCTURE FROM SLIDING
 AND OR TIPPING OVER. 2020 FBC-BUILDING CODE 1609.1.1
 DETERMINATION OF WIND LOADS.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MONDAY AUGUST 02ND/ 2021 ALL PLANS EXAMINERS WILL BE
 WORKING FROM CITY HALL.
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676