Plan Review Notes For Permit 21081013 |
Permit Number |
21081013 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2021-08-24 12:05:52 | 1ST REVIEW FBC- 2020 RES. BUILDING. | | PERMIT- 21020287 | | 8/24/2021 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE FLORIDA PRODUCT APPROVAL FOR THE TARCO | | UNDERLAYMENT- FL# 10950-R13 IS OUTDATED AND HAS BEEN | | REPLACED WITH FL# 10950-R14. THE FLORIDA PRODUCT | | APPROVAL FOR THE POLYGLASS UNDERLAYMENT- FL# 5259- R32 | | IS OUTDATED AND HAS BEEN REPLACED WITH FL# 5259- R33. | | PLEASE CLARIFY WHY TWO UNDERLAYMENT PRODUCT APPROVALS | | ARE BEING SUBMITTED? PLEASE CHOOSE ONE OR THE OTHER AND | | SUBMIT AN UPDATED PRODUCT APPROVAL INCLUDING THE COVER | | SHEETS, EVALUATION REPORT, AND INSTALLATION | | INSTRUCTIONS MARKED OR HIGHLIGHTED TO SHOW THE PRODUCT | | SELECTION AND INSTALLATION GUIDELINES- RULE 9N-3 FAC. | | | | 2) PLEASE INDICATE THE SLOPE OF THE TILE ROOF IN | | ACCORDANCE WITH R905.3.2 FBC RES. PLEASE NOTE THAT A | | MINIMUM 4/12 SLOPE IS REQUIRED FOR MECHANICALLY | | ATTACHED TILES- NOA 19-0814.01 PAGE 4 (NOTE 3.5). | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | BUILDING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|