2021-09-03 17:37:49RESIDENTIAL (R3) BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #21080665
  
 NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK
 SHALL COMPLY WITH THE MATERIALS AND METHODS
 REQUIREMENTS IN THE FLORIDA BUILDING CODE.
  
 1- REVISE SHUTTERS INSTALLATION SCHEDULE: SHUTTER SPAN
 FOR OPENINGS 15 AND 16 IS 133". NEED TO REVISE THE
 ANCHOR SPACING. SEE PAGE 13 OF 17 OF SHUTTERS PRODUCT
 APPROVAL SUBMITTED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 NOTE:
 MINIMUM EDGE DISTANCE SHOWN. CLEARLY SPECIFY IF THE
 EDGE DISTANCE SHOWN INCLUDES THE STUCCO THICKNESS OR
 NOT. THIS IS IMPORTANT BECAUSE IN THE FIELD THE ACTUAL
 EDGE DISTANCE NEED TO BE LARGER THAN THE ONE SHOWN ON
 THE SCHEDULE (TYPICALLY 1/2 MORE TO INCLUDE THE
 STUCCO).
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW.
 VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S
 OVERHEAD AND PROFIT AS REQUIRED BY SEC. 109.3 CITY
 AMENDMENTS. UPDATE VALUATION TO INCLUDE ALL COSTS OR
 PROVIDE COPY OF SIGNED CONTRACTS FOR BUILDING OFFICIAL
 CONSIDERATION.
  
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]