2021-09-16 14:33:40 | NEW SINGLE FAMILY RESIDENCE (R3) BUILDING REVIEW |
| COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #21080575 (MOTHER IN LAW HOUSE) |
| |
| 1- OK |
| |
| 2- ADDRESS AND PARCEL CONTROL NUMBER (PCN) SHOWN ON ALL |
| PLANS SUBMITTED IS INCORRECT. REVISE AS REQUIRED. |
| SEC. 107.2.1 CITY AMENDMENTS. |
| |
| RESPONSE: |
| PCN NUMBER SHOWN ON COVER PAGE STILL IS INCORRECT. |
| REVISE AS REQUIRED. THE ADDRESS ASSIGNED FOR THIS HOUSE |
| IS 1162 CARVER AVE NOT 0 CARVER AVE. REVISE ADDRESS ON |
| ALL DRAWINGS AS REQUIRED. |
| |
| 3- OK |
| 4- OK |
| |
| 5-LOT DRAINAGE |
| PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH THE |
| FOLLOWING: |
| R401.3 FBC-RESIDENTIAL. |
| SEC. 107.2.5 CITY AMENDMENTS. |
| SEC. 110.9 CITY AMENDMENTS. |
| |
| RESPONSE: |
| REPEAT COMMENT. NOT ADDRESSED. |
| |
| 6- REVISE ENERGY CALCULATIONS SUBMITTED: |
| A)ENERGY CALCULATIONS FORM IS REQUIRED TO BE CERTIFIED |
| AT THE BOTTOM OF THE FORM BY THE OWNER, THE OWNER'S |
| ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNED BY |
| THE OWNER PRIOR TO RECEIVE THE PERMIT AS REQUIRED BY |
| SEC. R103.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| ONLY THE FIRST PAGE OF FORM R405-2020 WITH THE OWNER |
| SIGNATURE WAS SUBMITTED. THE REMAINING OF THE ENERGY |
| CALCULATIONS REPORT WAS NOT SUBMITTED. PROVIDE COMPLETE |
| REPORT. |
| NOTE: FIRST PAGE NEEDS TO HAVE THE NAME OF THE PERSON |
| PREPARING THE ENERGY CALCULATIONS. |
| |
| B)PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP OF |
| FORM. PROVIDE CORRECT ADDRESS AND OWNER'S NAME, PROVIDE |
| NAME OF BUILDER, PERMITTING OFFICE AND JURISDICTION |
| NUMBER (THIS JURISDICTION IS 604700). |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| PROVIDE COMPLETE AND CORRECT ADDRESS. COORDINATE WITH |
| ITEM #2 ABOVE. |
| |
| C)OK |
| |
| D) DOORS INFORMATION ON PAGE 3 OF 4 IS INCORRECT. |
| (COORDINATE WITH ITEM #1 ABOVE). |
| THIS BUILDING IS FACING CARVER AVE. THESE DOORS ARE |
| LOCATED IN THE FRONT AND REAR OF BUILDING. SEE |
| SURVEY/SITE PLAN AND FLOOR PLAN AND REVISE AS REQUIRED. |
| . THEREFORE, THE CORRECT ORIENTATION IS WEST AND EAST. |
| REVISE AS REQUIRED. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| ONLY THE FIRST PAGE OF FORM R405-2020 WITH THE OWNER |
| SIGNATURE WAS SUBMITTED. THE REMAINING OF THE ENERGY |
| CALCULATIONS REPORT WAS NOT SUBMITTED. PROVIDE COMPLETE |
| REPORT. |
| |
| E)WINDOWS INFORMATION ON PAGE 3 OF 4 IS INCORRECT. |
| (COORDINATE WITH ITEM #1 ABOVE). |
| THIS BUILDING IS FACING CARVER AVE. SEE SURVEY/SITE |
| PLAN AND FLOOR PLAN AND REVISE AS REQUIRED. THERE ARE |
| NO WINDOWS ON THE SOUTH SIDE. |
| SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION. |
| |
| RESPONSE: |
| ONLY THE FIRST PAGE OF FORM R405-2020 WITH THE OWNER |
| SIGNATURE WAS SUBMITTED. THE REMAINING OF THE ENERGY |
| CALCULATIONS REPORT WAS NOT SUBMITTED. PROVIDE COMPLETE |
| REPORT. |
| |
| F)BUILDER TO SIGN AND COMPLETE THE ENERGY PERFORMANCE |
| LEVEL (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY |
| CONSERVATION. |
| |
| RESPONSE: |
| EPL FORM SUBMITTED IS FOR ANOTHER ADDRESS 1027 8TH ST.. |
| PROVIDE FORM FOR CORRECT ADDRESS. |
| |
| 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC |
| 61G20-3.001 FOR: |
| A)WINDOWS. |
| B)HURRICANE SHUTTERS IF WINDOWS DON'T HAVE IMPACT |
| GLAZING. AND, PROVIDE COMPLETE INSTALLATION SCHEDULE. |
| SEE CITY SAMPLE. |
| C)ROOF SHINGLES. |
| |
| 8-ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |