Date |
Text |
2021-09-20 10:38:37 | REVISION |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected] |
| CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 |
| AMENDMENTS |
| |
| CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| |
| 1) DOOR OUT SWING SHOWN IN THE CORRIDOR BETWEEN THE |
| BUILDINGS ON DRAWINGS A1.1, A1.0, A1.0A AND A2.0 |
| APPEARS TO BLOCK EGRESS PER FBC 1005.7.1 DOORS. |
| DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED |
| WIDTH BY MORE THAN 7 INCHES (178 MM). DOORS IN ANY |
| POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE |
| THAN ONE-HALF. |
| |
| 2) WALLS AROUND THE MOP SINK NEED TO COMPLY WITH FBC |
| 1210.2.2 WALLS AND PARTITIONS. |
| WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE |
| SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, |
| HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS |
| THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR |
| STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS |
| SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY |
| MOISTURE. (DRYWALL IS NOT CONSIDERED A HARD SURFACE) |
| |
| 3) ACCESSIBLE RESTROOMS = PLEASE SHOW THE TOILET REAR |
| GRAB BAR LOCATION DIMENSIONS FROM THE CENTER LINE OF |
| THE TOILET PER FBC A 604.5.2 REAR WALL. |
| THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG |
| MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER |
| CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 |
| INCHES (610 MM) MINIMUM ON THE OTHER SIDE. |
| |
| 4) ACCESSIBLE RESTROOM = PLEASE SHOW THE TOILET PAPER |
| DISPENSER LOCATION FROM THE FACE OF THE TOILET PER FBC |
| 604.7 DISPENSERS. |
| TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48 |
| INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND |
| SHALL NOT BE LOCATED BEHIND GRAB BARS. |
| |
| 5) ACCESSIBLE RESTROOM = PLEASE SHOW THE MIRROR |
| DIMENSION FROM THE FLOOR TO THE "REFLECTIVE SURFACE" |
| PER FBC 603.3 MIRRORS. |
| MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL |
| BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING |
| SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH |
| FLOOR OR GROUND. |
| |
| 6) PLEASE PROVIDE THE ENLARGED FLOOR PLAN FOR BUILDING |
| "A" |