2021-10-04 16:27:33FROM: RAY CARANCI, SENIOR LANDSCAPE PLANNER
 561-822-1462
 PROJECT: 6417 GEORGIA AVE. PERMIT 21080409
 OCTOBER 4, 2021
 I HAVE REVIEWED THE ABOVE REFERENCED PETITION, AND
 PROVIDE THE FOLLOWING COMMENTS:
  
 1. NOT SATISFIED. A PAVING PERMIT MUST BE SUBMITTED FOR
 AREAS OF PARKING CREATED ON THE SITE. THIS WILL REQUIRE
 ZONING, BUILDING AND ENGINEERING REVIEW, AND ANY
 LANDSCAPING REQUIRED FOR PARKING MUST BE PROVIDED ON
 THE LANDSCAPE PLAN.
 NO ADDITIONAL PERMITS HAVE BEEN SUBMITTED FOR SITE
 CHANGES. CONTACT BUILDING FOR FURTHER INFORMATION.
 10/4/21 SET UP A MEETING WITH PLANNING AND ZONING
 REGARDING CHANGE OF USE AND REQUIRED PARKING. THIS MAY
 CHANGE THE LANDSCAPE REQUIREMENTS FOR THE SITE.
  
 2. SATISFIED. PROVIDE THE CALCULATIONS FOR THE MINIMUM
 REQUIRED SHADE TREES, FLOWERING TREES AND SHRUBS FOR
 THE SITE BASED ON 40% OPEN SPACE PER SECTION
 94-442(C)(2)B.
 CORRECT THE MINIMUM SHADE TREE CALCULATION TO 1 PER
 1500 SQ FT OR PORTION THEREOF. REQUIRED FOR 4000 SQ FT
 IS 3 SHADE TREES.
 CORRECT THE MINIMUM SHRUB CALCULATION TO 1 PER 500 SQ
 FT OR PORTION THEREOF. REQUIRED FOR 4000 SQ FT IS 8
 SHRUBS.
  
  
 3. PARTIALLY SATISFIED. PER SECTION 94-443(B) PROVIDE
 THE 5 FOOT LANDSCAPE BUFFER FOR THE WEST BUFFER, AND
 THE 10 FOOT LANDSCAPE BUFFER ADJACENT TO THE PUBLIC
 THOROUGHFARE FOR THE PORTIONS OF THE NORTH AND SOUTH
 BUFFER THAT ARE NOT COVERED BY THE BUILDING AT ZERO
 SETBACK AND ADJACENT TO GEORGIA AVE. SHOW THE LENGTH OF
 ALL FOUR BUFFER SECTIONS AND SHOW THE REQUIRED AND
 PROVIDED TREES FOR EACH 30 FEET OR PORTION THEREOF.
 PROPOSED CURB CUT AND PARKING DO NOT MEET CURRENT CODE
 REQUIREMENTS SO WILL NEED TO BE DESIGNED TO MEET CODE.
 LANDSCAPE BUFFER WILL NEED TO BE ADJUSTED TO MATCH WHAT
 IS APPROVED.
  
 4. NOT SATISFIED. PROVIDE THE REQUIRED SCREEN WALL OR
 FENCE PER SECTION 94-443(A)(1) ALONG THE WEST PROPERTY
 LINE ADJACENT TO SINGLE FAMILY ZONING.
 FENCE PERMIT 21080196 WAS SUBMITTED WITH PLANS/SURVEY
 IN THE SUPPORTING DOCS FILE AND HAS NOT BEEN REVIEWED.
  
 5. SATISFIED. TREES CANNOT BE SHEARED INTO SHAPES PER
 SECTION 94-446(2), AND HEDGES ARE LIMITED TO 10 FEET IN
 HEIGHT. TREE HEDGES ARE NOT PERMITTED.
  
 6. SATISFIED. PER SECTION 94-442(G) PROVIDE THE
 REQUIRED 50 POINTS FORM THE FLORIDA FRIENDLY DESIGN
 OPTIONS LIST.
 CALOPHYLLUM IS NOT NATIVE TO FLORIDA. THIS CHANGES THE
 PERCENTAGE OF NATIVE TREES USED.
  
 7. SATISFIED. ADD COLUMNS FOR NATIVE AND DROUGHT
 TOLERANCE TO THE PLANT LIST.
 DROUGHT TOLERANCE COLUMN ADDED, ADD COLUMN FOR FLORIDA
 NATIVE.
 8. SATISFIED. PROVIDE A SECTION IN A LANDSCAPE DATA
 CHART TO COMPLY WITH SECTION 94-445 L. PLANT SPECIES. A
 MINIMUM OF 60 PERCENT OF PLANT MATERIAL ADDED SHALL BE
 FLORIDA NATIVE OR DROUGHT TOLERANT SPECIES SELECTED
 FROM THE CITY LIST OR THE LIST OF SPECIES IN THE MOST
 RECENT EDITION OF SOUTH FLORIDA WATER MANAGEMENT
 DISTRICT WATERWISE SOUTH FLORIDA LANDSCAPES. PROVIDE
 THE TOTAL PERCENTAGE OF NATIVE AND DROUGHT TOLERANT
 PLANTS BASED ON FINAL PLANT LIST.
 CALOPHYLLUM IS NOT FLORIDA NATIVE. RECALCULATE BASED ON
 TOTAL PLANTS ADDED.
  
 9. NOT SATISFIED. PER SECTION 94-443 (E)2., PROVIDE THE
 20% FOUNDATION PLANTING CALCULATION REQUIRED AND
 PROVIDED FOR THE ENTIRE BUILDING.
 CALCULATIONS MUST BE SHOWN ON THE PLANS.
  
 10. NOT SATISFIED. PROVIDE THE NUMBER AND PERCENTAGE OF
 SUBSTITUTION OF PALMS FOR REQUIRED TREES. SECTION
 94-442(D) REQUIRES A 3:1 RATIO FOR SUBSTITUTION FOR
 PALMS EXCEPT THE LISTED 1:1 SPECIES.
 CALCULATIONS MUST BE SHOWN ON THE PLANS.
  
 11. SATISFIED. PROVIDE LOCATIONS OF UTILITY LINES
 INCLUDING WATER, SEWER AND DRAINAGE AND RESOLVE
 CONFLICTS WITH LANDSCAPING.
 SHOW EXISTING AND PROPOSED UTILITIES.
  
 PROVIDE WRITTEN RESPONSES TO THE COMMENTS WITH
 RESUBMITTAL.
  