2021-10-27 14:55:32 | RESIDENTIAL (R2) FOURTH BUILDING REVIEW COMMENTS |
| CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| PERMIT #21080079 |
| |
| 10/27/21 SENT EMAIL TO ENGINEER AT |
| [email protected] STATING THAT THIS PROJECT |
| IS BEING DENIED 4 TIMES. JG. |
| |
| |
| ARCHITECTS-ENGINEERS |
| FLORIDA STATUTE 553.80(2)(B): |
| ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN |
| PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT |
| NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE |
| FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT |
| DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE |
| TIMES FOR FAILURE TO CORRECT A CODE VIOLATION |
| SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, |
| INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, |
| STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, |
| VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS |
| SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF |
| THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO |
| CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH |
| TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED |
| FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT |
| OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS |
| REVIEW |
| |
| |
| NOTE: SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK |
| SHALL COMPLY WITH THE MATERIALS AND METHODS |
| REQUIREMENTS IN THE FLORIDA BUILDING CODE. |
| |
| ORIGINAL COMMENT: |
| 1- DESIGN WIND PRESSURE CALCULATIONS SUBMITTED: |
| BASED ON THE AERIAL VIEWS ON THE PROPERTY APPRAISER |
| WEBSITE, IT LOOKS LIKE SOME OPENINGS ( WINDOW #6 AND |
| SLIDING GLASS DOORS) ARE IN THE END ZONE NOT IN THE |
| INTERIOR ZONE AND THE BUILDING DIMENSIONS ARE WRONG. |
| THIS IS CRITICAL BECAUSE PRODUCT APPROVALS SUBMITTED |
| MAY NOT MEET THE DESIGN PRESSURES. REVISE CALCULATIONS |
| SUBMITTED SHOWING THE OPENINGS THAT ARE LOCATED IN THE |
| END ZONE OR PROVIDE SITE SPECIFIC DESIGN WIND PRESSURES |
| SHOWING THE ACTUAL BUILDING DIMENSIONS AND WALL ZONES. |
| SEC. 107.2.1.2 CITY AMENDMENTS. |
| |
| RESPONSE: |
| REPEAT COMMENT. REVISED CALCULATIONS SUBMITTED ON |
| 10/21/21 ARE WRONG. STRUCTURE INFORMATION IS WRONG. |
| ENGINEER OF RECORD NEEDS TO SEE THE BUILDING AND REVISE |
| THIS INFORMATION TO MATCH ACTUAL BUILDING CONDITIONS. |
| AS MENTIONED BEFORE, IT LOOKS LIKE SOME OPENINGS ( |
| WINDOW #6 AND SLIDING GLASS DOORS) ARE IN THE END ZONE |
| NOT IN THE INTERIOR ZONE. REVISE CALCULATIONS SUBMITTED |
| SHOWING THE OPENINGS THAT ARE LOCATED IN THE END ZONE |
| OR PROVIDE SITE SPECIFIC DESIGN WIND PRESSURES SHOWING |
| THE ACTUAL BUILDING DIMENSIONS AND WALL ZONES. SEC. |
| 107.2.1.2 CITY AMENDMENTS. |
| |
| |
| 2- PRODUCT APPROVALS SUBMITTED WILL BE REVIEWED ONCE |
| THE DESIGN WIND PRESSURES ARE REVISED. PLEASE CHECK |
| PRODUCT APPROVALS SUBMITTED MEET THE REVISED DESIGN |
| PRESSURES. OTHERWISE NEW PRODUCT APPROVALS ARE |
| REQUIRED. |
| SEC. 107.2.1 CITY AMENDMENTS. |
| |
| 3- WINDOW MULLIONS PRODUCT APPROVAL SUBMITTED: |
| CLEARLY SPECIFY MULLION SIZE TO BE USED TO VERIFY |
| COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. |
| SEC. 107.2.1 CITY AMENDMENTS. |
| REPEAT COMMENT. |
| |
| |
| NOTE: SEE SEC. 702.4 FBC-EXISTING BUILDING CODE. WINDOW |
| OPENING CONTROL DEVICES IN WINDOW REPLACEMENT ARE |
| REQUIRED WHEN THE FOLLOWING APPLY: |
| IN GROUP R-2 OR R-3 BUILDINGS CONTAINING DWELLING UNITS |
| AND ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES |
| REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL, |
| WINDOW OPENING CONTROL DEVICES COMPLYING WITH ASTM |
| F2090 SHALL BE INSTALLED WHERE AN EXISTING WINDOW IS |
| REPLACED AND WHERE ALL OF THE FOLLOWING APPLY TO THE |
| REPLACEMENT WINDOW: |
| 1.THE WINDOW IS OPERABLE; |
| 2. THE WINDOW REPLACEMENT INCLUDES REPLACEMENT OF THE |
| SASH AND THE FRAME; |
| 3.ONE OF THE FOLLOWING APPLIES: |
| 3.1.IN GROUP R-2 OR R-3 BUILDINGS CONTAINING DWELLING |
| UNITS, THE TOP OF THE SILL OF THE WINDOW OPENING IS AT |
| A HEIGHT LESS THAN 36 INCHES (915 MM) ABOVE THE |
| FINISHED FLOOR; OR |
| 3.2. IN ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES |
| REGULATED BY THE FLORIDA BUILDING CODE, RESIDENTIAL, |
| THE TOP SILL OF THE WINDOW OPENING IS AT A HEIGHT LESS |
| THAN 24 INCHES (610 MM) ABOVE THE FINISHED FLOOR; |
| 4.THE WINDOW WILL PERMIT OPENINGS THAT WILL ALLOW |
| PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE WHEN THE |
| WINDOW IS IN ITS LARGEST OPENED POSITION; AND |
| 5.THE VERTICAL DISTANCE FROM THE TOP OF THE SILL OF THE |
| WINDOW OPENING TO THE FINISHED GRADE OR OTHER SURFACE |
| BELOW, ON THE EXTERIOR OF THE BUILDING, IS GREATER THAN |
| 72 INCHES (1829 MM). |
| THE WINDOW OPENING CONTROL DEVICE, AFTER OPERATION TO |
| RELEASE THE CONTROL DEVICE ALLOWING THE WINDOW TO FULLY |
| OPEN, SHALL NOT REDUCE THE MINIMUM NET CLEAR OPENING |
| AREA OF THE WINDOW UNIT TO LESS THAN THE AREA REQUIRED |
| BY THE FLORIDA BUILDING CODE, BUILDING |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |