Date |
Text |
2021-08-19 10:29:09 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR EMAIL [email protected] AND REQUEST |
| THAT IT BE CONVERTED TO PROJECTDOX. |
| |
| 1. SUBMITTED PRODUCT APPROVAL FL14724-R11 HAS BEEN |
| REVISED TO FL14724-R12. PLEASE PROVIDE A COMPLETE SET. |
| ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY |
| IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS |
| AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT |
| APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER |
| RULE 61G20-3. |
| 2. FBC B 107.2.1. PLEASE PROVIDE ENGINEER'S SIGNED AND |
| SEALED FASTENER SPACING DETAIL WITH CALCULATIONS FOR |
| PERIMETERS AND CORNERS AS PER PRODUCT APPROVAL |
| FL17442-R6 LIMITATIONS #7. |
| 3. FBC EB 706.3(1) PROVIDE A SIGNED AND SEALED MOISTURE |
| REPORT PREPARED BY A FLORIDA REGISTERED DESIGN |
| PROFESSIONAL. |
| 4. PROVIDE FIELD UPLIFT TESTING IN ACCORDANCE WITH |
| TESTING APPLICATION STANDARD TAS 124 AS REQUIRED BY |
| LIMITATIONS #8 OF PRODUCT APPROVAL FL17442-R6. |
| 5. FBC R 301 FAC9N-3 SUBMITTED STATE OF FLORIDA PRODUCT |
| APPROVAL FL17442-R6 COVERS MULTIPLE PRODUCTS; |
| COMPONENTS & APPROVED ASSEMBLIES. ALL APPLICABLE |
| DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON |
| THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS |
| NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED |
| SITE-SPECIFIC ENGINEERING. |
| 6. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A COMPLETE |
| ROOF DIAGRAM/SKETCH SHOWING ALL AREAS AND THE AREAS TO |
| RECEIVE NEW ROOFING CLEARLY IDENTIFIED ON DRAWING; |
| INCLUDE ROOF SLOPE(S), ROOF HEIGHT, DECK TYPE & |
| EXISTING COVERINGS. (IF APPLICABLE) |
| |