Plan Review Notes
Plan Review Notes For Permit 21071464
Permit Number 21071464
Review Stop P
Sequence Number 1
Notes
Date Text
2021-08-12 08:12:401ST REVIEW FBC-2020 RES. PLUMBING.
 PERMIT- 21071464
 8/12/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 3: THE TDH CALCULATIONS APPEAR TO MISSING THE
 2.5 SUCTION LINE. PLEASE LABEL THE PIPING CALCULATED AS
 EITHER PRESSURE OR SUCTION- SECTION 4.4.4.9.1
 ANSI/APSP/ICC-7- 2013.
  
 2) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE PUMP
 AND FILTER- SECTIONS R4501.7 & R4501.20 FBC RES.
  
 3) IN ACCORDANCE WITH SECTION 4.3.1 ANSI/APSP/ICC-7-
 2013, SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE
 SUCTION OUTLET ASSEMBLY INCLUDING THE COVER/GRATE
 VERIFYING COMPLIANCE WITH ANSI/APSP-16 AND SECTION
 A112.19.8A.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719